4
5class BRICK(DefinedNamespace):
6 """
7 Brick Ontology classes, properties and entity properties. See https://brickschema.org/
8 for more information.
9
10 Generated from: https://github.com/BrickSchema/Brick/releases/download/nightly/Brick.ttl
11 Date: 2021-09-22T14:32:56
12 """
13
14 # http://www.w3.org/2002/07/owl#Class
15 AED: URIRef
16 AHU: URIRef # Assembly consisting of sections containing a fan or fans and other necessary equipment to perform one or more of the following functions: circulating, filtration, heating, cooling, heat recovery, humidifying, dehumidifying, and mixing of air. Is usually connected to an air-distribution system.
17 Ablutions_Room: URIRef # A room for performing cleansing rituals before prayer
18 Absorption_Chiller: URIRef # A chiller that utilizes a thermal or/and chemical process to produce the refrigeration effect necessary to provide chilled water. There is no mechanical compression of the refrigerant taking place within the machine, as occurs within more traditional vapor compression type chillers.
19 Acceleration_Time_Setpoint: URIRef
20 Access_Control_Equipment: URIRef
21 Access_Reader: URIRef
22 Active_Chilled_Beam: URIRef # A Chilled Beam with an integral primary air connection that induces air flow through the device.
23 Active_Power_Sensor: URIRef # Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction
24 Adjust_Sensor: URIRef # Measures user-provided adjustment of some value
25 Air: URIRef # the invisible gaseous substance surrounding the earth, a mixture mainly of oxygen and nitrogen.
26 Air_Alarm: URIRef
27 Air_Differential_Pressure_Sensor: (
28 URIRef # Measures the difference in pressure between two regions of air
29 )
30 Air_Differential_Pressure_Setpoint: URIRef # Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit
31 Air_Diffuser: URIRef # A device that is a component of the air distribution system that controls the delivery of conditioned and/or ventilating air into a room
32 Air_Enthalpy_Sensor: URIRef # Measures the total heat content of air
33 Air_Flow_Deadband_Setpoint: URIRef # Sets the size of a deadband of air flow
34 Air_Flow_Demand_Setpoint: URIRef # Sets the rate of air flow required for a process
35 Air_Flow_Loss_Alarm: URIRef # An alarm that indicates loss in air flow.
36 Air_Flow_Sensor: URIRef # Measures the rate of flow of air
37 Air_Flow_Setpoint: URIRef # Sets air flow
38 Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint.
39 Air_Grains_Sensor: URIRef # Measures the mass of water vapor in air
40 Air_Handler_Unit: URIRef # Assembly consisting of sections containing a fan or fans and other necessary equipment to perform one or more of the following functions: circulating, filtration, heating, cooling, heat recovery, humidifying, dehumidifying, and mixing of air. Is usually connected to an air-distribution system.
41 Air_Handling_Unit: URIRef
42 Air_Humidity_Setpoint: URIRef
43 Air_Loop: URIRef # The set of connected equipment serving one path of air
44 Air_Plenum: URIRef # A component of the HVAC the receives air from the air handling unit or room to distribute or exhaust to or from the building
45 Air_Quality_Sensor: URIRef # A sensor which provides a measure of air quality
46 Air_Static_Pressure_Step_Parameter: URIRef
47 Air_System: URIRef # The equipment, distribution systems and terminals that introduce or exhaust, either collectively or individually, the air into and from the building
48 Air_Temperature_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with the temperature of air.
49 Air_Temperature_Integral_Time_Parameter: URIRef
50 Air_Temperature_Sensor: URIRef # Measures the temperature of air
51 Air_Temperature_Setpoint: URIRef # Sets temperature of air
52 Air_Temperature_Setpoint_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint.
53 Air_Temperature_Step_Parameter: URIRef
54 Air_Wet_Bulb_Temperature_Sensor: URIRef
55 Alarm: URIRef # Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action
56 Alarm_Delay_Parameter: URIRef # A parameter determining how long to delay an alarm after sufficient conditions have been met
57 Angle_Sensor: URIRef # Measues the planar angle of some phenomenon
58 Auditorium: URIRef # A space for performances or larger gatherings
59 Automated_External_Defibrillator: URIRef
60 Automatic_Mode_Command: URIRef # Controls whether or not a device or controller is operating in "Automatic" mode
61 Availability_Status: URIRef # Indicates if a piece of equipment, system, or functionality is available for operation
62 Average_Cooling_Demand_Sensor: URIRef # Measures the average power consumed by a cooling process as the amount of power consumed over some interval
63 Average_Discharge_Air_Flow_Sensor: (
64 URIRef # The computed average flow of discharge air over some interval
65 )
66 Average_Exhaust_Air_Static_Pressure_Sensor: URIRef # The computed average static pressure of air in exhaust regions of an HVAC system over some period of time
67 Average_Heating_Demand_Sensor: URIRef # Measures the average power consumed by a heating process as the amount of power consumed over some interval
68 Average_Supply_Air_Flow_Sensor: (
69 URIRef # The computed average flow of supply air over some interval
70 )
71 Average_Zone_Air_Temperature_Sensor: URIRef # The computed average temperature of air in a zone, over some period of time
72 Baseboard_Radiator: URIRef # Steam, hydronic, or electric heating device located at or near the floor.
73 Basement: URIRef # The floor of a building which is partly or entirely below ground level.
74 Battery: URIRef # A container that stores chemical energy that can be converted into electricity and used as a source of power
75 Battery_Energy_Storage_System: URIRef # A collection of batteries that provides energy storage, along with their supporting equipment
76 Battery_Room: URIRef # A room used to hold batteries for backup power
77 Battery_Voltage_Sensor: URIRef # Measures the capacity of a battery
78 Bench_Space: URIRef # For areas of play in a stadium, the area for partcipants and referees by the side of the field
79 Blowdown_Water: URIRef # Water expelled from a system to remove mineral build up
80 Boiler: URIRef # A closed, pressure vessel that uses fuel or electricity for heating water or other fluids to supply steam or hot water for heating, humidification, or other applications.
81 Booster_Fan: URIRef # Fan activated to increase airflow beyond what is provided by the default configuration
82 Box_Mode_Command: URIRef
83 Break_Room: URIRef # A space for people to relax while not working
84 Breaker_Panel: URIRef # Breaker Panel distributes power into various end-uses.
85 Breakroom: URIRef # A space for people to relax while not working
86 Broadcast_Room: (
87 URIRef # A space to organize and manage a broadcast. Separate from studio
88 )
89 Building: URIRef # An independent unit of the built environment with a characteristic spatial structure, intended to serve at least one function or user activity [ISO 12006-2:2013]
90 Building_Air: URIRef # air contained within a building
91 Building_Air_Humidity_Setpoint: URIRef # Setpoint for humidity in a building
92 Building_Air_Static_Pressure_Sensor: (
93 URIRef # The static pressure of air within a building
94 )
95 Building_Air_Static_Pressure_Setpoint: (
96 URIRef # Sets static pressure of the entire building
97 )
98 Building_Chilled_Water_Meter: URIRef # A meter that measures the usage or consumption of chilled water of a whole building
99 Building_Electrical_Meter: URIRef # A meter that measures the usage or consumption of electricity of a whole building
100 Building_Gas_Meter: URIRef # A meter that measures the usage or consumption of gas of a whole building
101 Building_Hot_Water_Meter: URIRef # A meter that measures the usage or consumption of hot water of a whole building
102 Building_Meter: URIRef # A meter that measures usage or consumption of some media for a whole building
103 Building_Water_Meter: URIRef # A meter that measures the usage or consumption of water of a whole building
104 Bus_Riser: URIRef # Bus Risers are commonly fed from a switchgear and rise up through a series of floors to the main power distribution source for each floor.
105 Bypass_Air: URIRef # air in a bypass duct, used to relieve static pressure
106 Bypass_Air_Flow_Sensor: URIRef # Measures the rate of flow of bypass air
107 Bypass_Air_Humidity_Setpoint: URIRef # Humidity setpoint for bypass air
108 Bypass_Command: URIRef
109 Bypass_Valve: URIRef # A type of valve installed in a bypass pipeline
110 Bypass_Water: URIRef # Water that circumvents a piece of equipment or system
111 Bypass_Water_Flow_Sensor: URIRef # Measures the rate of flow of bypass water
112 Bypass_Water_Flow_Setpoint: URIRef # Sets the target flow rate of bypass water
113 CAV: URIRef
114 CO: URIRef # Carbon Monoxide in the vapor phase
115 CO2: URIRef # Carbon Dioxide in the vapor phase
116 CO2_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide.
117 CO2_Differential_Sensor: (
118 URIRef # Measures the difference between CO2 levels of inside and outside air
119 )
120 CO2_Level_Sensor: URIRef # Measures the concentration of CO2 in air
121 CO2_Sensor: URIRef # Measures properties of CO2 in air
122 CO2_Setpoint: URIRef # Sets some property of CO2
123 CO_Differential_Sensor: URIRef
124 CO_Level_Sensor: URIRef # Measures the concentration of CO
125 CO_Sensor: URIRef # Measures properties of CO
126 CRAC: URIRef
127 Cafeteria: URIRef # A space to serve food and beverages
128 Camera: URIRef
129 Capacity_Sensor: URIRef
130 Ceiling_Fan: URIRef # A fan installed on the ceiling of a room for the purpose of air circulation
131 Centrifugal_Chiller: URIRef # A chiller that uses the vapor compression cycle to chill water. It throws off the heat collected from the chilled water plus the heat from the compressor to a water loop
132 Change_Filter_Alarm: URIRef # An alarm that indicates that a filter must be changed
133 Chilled_Beam: URIRef # A device with an integrated coil that performs sensible heating of a space via circulation of room air. Chilled Beams are not designed to perform latent cooling; see Induction Units. Despite their name, Chilled Beams may perform heating or cooling of a space depending on their configuration.
134 Chilled_Water: URIRef # water used as a cooling medium (particularly in air-conditioning systems or in processes) at below ambient temperature.
135 Chilled_Water_Coil: URIRef # A cooling element made of pipe or tube that removes heat from equipment, machines or airflows that is filled with chilled water.
136 Chilled_Water_Differential_Pressure_Deadband_Setpoint: (
137 URIRef # Sets the size of a deadband of differential pressure of chilled water
138 )
139 Chilled_Water_Differential_Pressure_Integral_Time_Parameter: URIRef
140 Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status: URIRef
141 Chilled_Water_Differential_Pressure_Load_Shed_Setpoint: URIRef
142 Chilled_Water_Differential_Pressure_Load_Shed_Status: URIRef
143 Chilled_Water_Differential_Pressure_Proportional_Band_Parameter: URIRef
144 Chilled_Water_Differential_Pressure_Sensor: URIRef # Measures the difference in water pressure on either side of a chilled water valve
145 Chilled_Water_Differential_Pressure_Setpoint: URIRef # Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water
146 Chilled_Water_Differential_Pressure_Step_Parameter: URIRef
147 Chilled_Water_Differential_Temperature_Sensor: URIRef # Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device
148 Chilled_Water_Discharge_Flow_Sensor: (
149 URIRef # Measures the rate of flow of chilled discharge water
150 )
151 Chilled_Water_Discharge_Flow_Setpoint: (
152 URIRef # Sets the target flow rate of chilled discharge water
153 )
154 Chilled_Water_Flow_Sensor: (
155 URIRef # Measures the rate of flow in a chilled water circuit
156 )
157 Chilled_Water_Flow_Setpoint: URIRef # Sets the target flow rate of chilled water
158 Chilled_Water_Loop: URIRef # A collection of equipment that transport and regulate chilled water among each other
159 Chilled_Water_Meter: (
160 URIRef # A meter that measures the usage or consumption of chilled water
161 )
162 Chilled_Water_Pump: URIRef # A pump that performs work on chilled water; typically part of a chilled water system
163 Chilled_Water_Pump_Differential_Pressure_Deadband_Setpoint: URIRef # Sets the size of a deadband of differential pressure of chilled water in a chilled water pump
164 Chilled_Water_Return_Flow_Sensor: (
165 URIRef # Measures the rate of flow of chilled return water
166 )
167 Chilled_Water_Return_Temperature_Sensor: URIRef # Measures the temperature of chilled water that is returned to a cooling tower
168 Chilled_Water_Static_Pressure_Setpoint: (
169 URIRef # Sets static pressure of chilled water
170 )
171 Chilled_Water_Supply_Flow_Sensor: (
172 URIRef # Measures the rate of flow of chilled supply water
173 )
174 Chilled_Water_Supply_Flow_Setpoint: (
175 URIRef # Sets the target flow rate of chilled supply water
176 )
177 Chilled_Water_Supply_Temperature_Sensor: URIRef # Measures the temperature of chilled water that is supplied from a chiller
178 Chilled_Water_System: URIRef # The equipment, devices and conduits that handle the production and distribution of chilled water in a building
179 Chilled_Water_System_Enable_Command: (
180 URIRef # Enables operation of the chilled water system
181 )
182 Chilled_Water_Temperature_Sensor: (
183 URIRef # Measures the temperature of chilled water
184 )
185 Chilled_Water_Temperature_Setpoint: URIRef # Sets the temperature of chilled water
186 Chilled_Water_Valve: URIRef # A valve that modulates the flow of chilled water
187 Chiller: URIRef # Refrigerating machine used to transfer heat between fluids. Chillers are either direct expansion with a compressor or absorption type.
188 Class: URIRef
189 Close_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint.
190 Coil: URIRef # Cooling or heating element made of pipe or tube that may or may not be finned and formed into helical or serpentine shape (ASHRAE Dictionary)
191 Cold_Box: URIRef # in a gas separation unit, the insulated section that contains the low-temperature heat exchangers and distillation columns.
192 Coldest_Zone_Air_Temperature_Sensor: URIRef # The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor'
193 Collection: URIRef
194 Collection_Basin_Water: URIRef # Water transiently collected and directed to the sump or pump suction line, typically integral with a cooling tower
195 Collection_Basin_Water_Heater: URIRef # Basin heaters prevent cold water basin freeze-up, e.g. in cooling towers, closed circuit fluid coolers, or evaporative condensers
196 Collection_Basin_Water_Level_Alarm: URIRef # An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower
197 Collection_Basin_Water_Level_Sensor: URIRef # Measures the level of the water in the collection basin, e.g. within a Cooling_Tower
198 Collection_Basin_Water_Temperature_Sensor: URIRef # Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower
199 Command: URIRef # A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points.
200 Common_Space: (
201 URIRef # A class of spaces that are used by multiple people at the same time
202 )
203 Communication_Loss_Alarm: URIRef # An alarm that indicates a loss of communication e.g. with a device or controller
204 Compressor: URIRef # (1) device for mechanically increasing the pressure of a gas. (2) often described as being either open, hermetic, or semihermetic to describe how the compressor and motor drive is situated in relation to the gas or vapor being compressed. Types include centrifugal, axial flow, reciprocating, rotary screw, rotary vane, scroll, or diaphragm. 1. device for mechanically increasing the pressure of a gas. 2. specific machine, with or without accessories, for compressing refrigerant vapor.
205 Computer_Room_Air_Conditioning: URIRef # A device that monitors and maintains the temperature, air distribution and humidity in a network room or data center.
206 Concession: URIRef # A space to sell food and beverages. Usually embedded in a larger space and does not include a space where people consume their purchases
207 Condensate_Leak_Alarm: (
208 URIRef # An alarm that indicates a leak of condensate from a cooling system
209 )
210 Condenser: URIRef # A heat exchanger in which the primary heat transfer vapor changes its state to a liquid phase.
211 Condenser_Heat_Exchanger: URIRef # A heat exchanger in which the primary heat transfer vapor changes its state to a liquid phase.
212 Condenser_Water: URIRef # Water used used to remove heat through condensation
213 Condenser_Water_Bypass_Valve: (
214 URIRef # A valve installed in a bypass line of a condenser water loop
215 )
216 Condenser_Water_Isolation_Valve: (
217 URIRef # An isolation valve installed in the condenser water loop
218 )
219 Condenser_Water_Pump: URIRef # A pump that is part of a condenser system; the pump circulates condenser water from the chiller back to the cooling tower
220 Condenser_Water_System: URIRef # A heat rejection system consisting of (typically) cooling towers, condenser water pumps, chillers and the piping connecting the components
221 Condenser_Water_Temperature_Sensor: (
222 URIRef # Measures the temperature of condenser water
223 )
224 Condenser_Water_Valve: URIRef # A valve that modulates the flow of condenser water
225 Condensing_Natural_Gas_Boiler: URIRef # A closed, pressure vessel that uses natural gas and heat exchanger that capture and reuse any latent heat for heating water or other fluids to supply steam or hot water for heating, humidification, or other applications.
226 Conductivity_Sensor: URIRef # Measures electrical conductance
227 Conference_Room: URIRef # A space dedicated in which to hold a meetings
228 Constant_Air_Volume_Box: URIRef # A terminal unit for which supply air flow rate is constant and the supply air temperature is varied to meet thermal load
229 Contact_Sensor: URIRef # Senses or detects contact, such as for determining if a door is closed.
230 Control_Room: URIRef # A space from which operations are managed
231 Cooling_Coil: URIRef # A cooling element made of pipe or tube that removes heat from equipment, machines or airflows. Typically filled with either refrigerant or cold water.
232 Cooling_Command: URIRef # Controls the amount of cooling to be delivered (typically as a proportion of total cooling output)
233 Cooling_Demand_Sensor: URIRef # Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton
234 Cooling_Demand_Setpoint: URIRef # Sets the rate required for cooling
235 Cooling_Discharge_Air_Flow_Setpoint: URIRef # Sets discharge air flow for cooling
236 Cooling_Discharge_Air_Temperature_Deadband_Setpoint: (
237 URIRef # Sets the size of a deadband of temperature of cooling discharge air
238 )
239 Cooling_Discharge_Air_Temperature_Integral_Time_Parameter: URIRef
240 Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter: URIRef
241 Cooling_Start_Stop_Status: URIRef
242 Cooling_Supply_Air_Flow_Setpoint: URIRef # Sets supply air flow rate for cooling
243 Cooling_Supply_Air_Temperature_Deadband_Setpoint: (
244 URIRef # Sets the size of a deadband of temperature of supply air for cooling
245 )
246 Cooling_Supply_Air_Temperature_Integral_Time_Parameter: URIRef
247 Cooling_Supply_Air_Temperature_Proportional_Band_Parameter: URIRef
248 Cooling_Temperature_Setpoint: URIRef # Sets temperature for cooling
249 Cooling_Tower: URIRef # A cooling tower is a heat rejection device that rejects waste heat to the atmosphere through the cooling of a water stream to a lower temperature. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid to near the wet-bulb air temperature or, in the case of closed circuit dry cooling towers, rely solely on air to cool the working fluid to near the dry-bulb air temperature.
250 Cooling_Tower_Fan: URIRef # A fan that pulls air through a cooling tower and across the louvers where the water falls to aid in heat exchange by the process of evaporation
251 Cooling_Valve: URIRef # A valve that controls air temperature by modulating the amount of cold water flowing through a cooling coil
252 Copy_Room: URIRef # A room set aside for common office equipment, including printers and copiers
253 Core_Temperature_Sensor: URIRef # Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system.
254 Core_Temperature_Setpoint: URIRef # Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel.
255 Cubicle: URIRef # A smaller space set aside for an individual, but not with a door and without full-height walls
256 Current_Imbalance_Sensor: URIRef # A sensor which measures the current difference (imbalance) between phases of an electrical system
257 Current_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint.
258 Current_Output_Sensor: URIRef # Senses the amperes of electrical current produced as output by a device
259 Current_Sensor: (
260 URIRef # Senses the amperes of electrical current passing through the sensor
261 )
262 Curtailment_Override_Command: URIRef
263 Cycle_Alarm: URIRef # An alarm that indicates off-normal conditions associated with HVAC cycles
264 DC_Bus_Voltage_Sensor: URIRef # Measures the voltage across a DC bus
265 DOAS: URIRef # See Dedicated_Outdoor_Air_System_Unit
266 Damper: URIRef # Element inserted into an air-distribution system or element of an air-distribution system permitting modification of the air resistance of the system and consequently changing the airflow rate or shutting off the airflow.
267 Damper_Command: URIRef # Controls properties of dampers
268 Damper_Position_Command: (
269 URIRef # Controls the position (the degree of openness) of a damper
270 )
271 Damper_Position_Sensor: URIRef # Measures the current position of a damper in terms of the percent of fully open
272 Damper_Position_Setpoint: URIRef # Sets the position of damper
273 Deadband_Setpoint: URIRef # Sets the size of a deadband
274 Deceleration_Time_Setpoint: URIRef
275 Dedicated_Outdoor_Air_System_Unit: URIRef # A device that conditions and delivers 100% outdoor air to its assigned spaces. It decouples air-conditioning of the outdoor air, usually used to provide minimum outdoor air ventilation, from conditioning of the internal loads.
276 Dehumidification_Start_Stop_Status: URIRef
277 Deionised_Water_Conductivity_Sensor: (
278 URIRef # Measures the electrical conductance of deionised water
279 )
280 Deionised_Water_Level_Sensor: (
281 URIRef # Measures the height/level of deionised water in some container
282 )
283 Deionized_Water: URIRef # Water which has been purified by removing its ions (constituting the majority of non-particulate contaminants)
284 Deionized_Water_Alarm: URIRef # An alarm that indicates deionized water leaks.
285 Delay_Parameter: URIRef # A parameter determining how long to delay a subsequent action to take place after a received signal
286 Demand_Sensor: URIRef # Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton
287 Demand_Setpoint: URIRef # Sets the rate required for a process
288 Derivative_Gain_Parameter: URIRef
289 Derivative_Time_Parameter: URIRef
290 Detention_Room: (
291 URIRef # A space for the temporary involuntary confinement of people
292 )
293 Dew_Point_Setpoint: URIRef # Sets dew point
294 Dewpoint_Sensor: URIRef # Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor
295 Differential_Air_Temperature_Setpoint: (
296 URIRef # Sets temperature of differential air
297 )
298 Differential_Pressure_Bypass_Valve: URIRef # A 2-way, self contained proportional valve with an integral differential pressure adjustment setting.
299 Differential_Pressure_Deadband_Setpoint: (
300 URIRef # Sets the size of a deadband of differential pressure
301 )
302 Differential_Pressure_Integral_Time_Parameter: URIRef
303 Differential_Pressure_Load_Shed_Status: URIRef
304 Differential_Pressure_Proportional_Band: URIRef
305 Differential_Pressure_Sensor: (
306 URIRef # Measures the difference between two applied pressures
307 )
308 Differential_Pressure_Setpoint: URIRef # Sets differential pressure
309 Differential_Pressure_Setpoint_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint.
310 Differential_Pressure_Step_Parameter: URIRef
311 Differential_Speed_Sensor: URIRef
312 Differential_Speed_Setpoint: URIRef # Sets differential speed
313 Differential_Supply_Return_Water_Temperature_Sensor: URIRef # Measures the difference in temperature between return and supply water of water a circuit
314 Dimmer: URIRef # A switch providing continuous control over all or part of a lighting installation; typically potentiometer-based
315 Direct_Expansion_Cooling_Coil: URIRef
316 Direct_Expansion_Heating_Coil: URIRef
317 Direction_Command: URIRef # Commands that affect the direction of some phenomenon
318 Direction_Sensor: (
319 URIRef # Measures the direction in degrees in which a phenomenon is occurring
320 )
321 Direction_Status: URIRef # Indicates which direction a device is operating in
322 Disable_Command: URIRef # Commands that disable functionality
323 Disable_Differential_Enthalpy_Command: (
324 URIRef # Disables the use of differential enthalpy control
325 )
326 Disable_Differential_Temperature_Command: (
327 URIRef # Disables the use of differential temperature control
328 )
329 Disable_Fixed_Enthalpy_Command: URIRef # Disables the use of fixed enthalpy control
330 Disable_Fixed_Temperature_Command: (
331 URIRef # Disables the use of fixed temperature temperature
332 )
333 Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint: URIRef # Disables hot water system when outside air temperature reaches the indicated value
334 Disable_Status: URIRef # Indicates if functionality has been disabled
335 Discharge_Air: URIRef # the air exiting the registers (vents).
336 Discharge_Air_Dewpoint_Sensor: URIRef # Measures dewpoint of discharge air
337 Discharge_Air_Duct_Pressure_Status: (
338 URIRef # Indicates if air pressure in discharge duct is within expected bounds
339 )
340 Discharge_Air_Flow_Demand_Setpoint: (
341 URIRef # Sets the rate of discharge air flow required for a process
342 )
343 Discharge_Air_Flow_High_Reset_Setpoint: URIRef
344 Discharge_Air_Flow_Low_Reset_Setpoint: URIRef
345 Discharge_Air_Flow_Reset_Setpoint: URIRef # Setpoints used in Reset strategies
346 Discharge_Air_Flow_Sensor: URIRef # Measures the rate of flow of discharge air
347 Discharge_Air_Flow_Setpoint: URIRef # Sets discharge air flow
348 Discharge_Air_Humidity_Sensor: (
349 URIRef # Measures the relative humidity of discharge air
350 )
351 Discharge_Air_Humidity_Setpoint: URIRef # Humidity setpoint for discharge air
352 Discharge_Air_Smoke_Detection_Alarm: URIRef
353 Discharge_Air_Static_Pressure_Deadband_Setpoint: (
354 URIRef # Sets the size of a deadband of static pressure of discharge air
355 )
356 Discharge_Air_Static_Pressure_Integral_Time_Parameter: URIRef
357 Discharge_Air_Static_Pressure_Proportional_Band_Parameter: URIRef
358 Discharge_Air_Static_Pressure_Sensor: (
359 URIRef # The static pressure of air within discharge regions of an HVAC system
360 )
361 Discharge_Air_Static_Pressure_Setpoint: (
362 URIRef # Sets static pressure of discharge air
363 )
364 Discharge_Air_Static_Pressure_Step_Parameter: URIRef
365 Discharge_Air_Temperature_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with the temperature of discharge air.
366 Discharge_Air_Temperature_Cooling_Setpoint: (
367 URIRef # Sets temperature of discharge air for cooling
368 )
369 Discharge_Air_Temperature_Deadband_Setpoint: (
370 URIRef # Sets the size of a deadband of temperature of discharge air
371 )
372 Discharge_Air_Temperature_Heating_Setpoint: (
373 URIRef # Sets temperature of discharge air for heating
374 )
375 Discharge_Air_Temperature_High_Reset_Setpoint: URIRef
376 Discharge_Air_Temperature_Low_Reset_Setpoint: URIRef
377 Discharge_Air_Temperature_Proportional_Band_Parameter: URIRef
378 Discharge_Air_Temperature_Reset_Differential_Setpoint: URIRef
379 Discharge_Air_Temperature_Sensor: (
380 URIRef # Measures the temperature of discharge air
381 )
382 Discharge_Air_Temperature_Setpoint: URIRef # Sets temperature of discharge air
383 Discharge_Air_Temperature_Setpoint_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint.
384 Discharge_Air_Temperature_Step_Parameter: URIRef
385 Discharge_Air_Velocity_Pressure_Sensor: URIRef
386 Discharge_Chilled_Water: URIRef
387 Discharge_Fan: URIRef # Fan moving air discharged from HVAC vents
388 Discharge_Hot_Water: URIRef
389 Discharge_Water: URIRef
390 Discharge_Water_Differential_Pressure_Deadband_Setpoint: URIRef # Sets the size of a deadband of differential pressure of discharge water
391 Discharge_Water_Differential_Pressure_Integral_Time_Parameter: URIRef
392 Discharge_Water_Differential_Pressure_Proportional_Band_Parameter: URIRef
393 Discharge_Water_Flow_Sensor: URIRef # Measures the rate of flow of discharge water
394 Discharge_Water_Flow_Setpoint: (
395 URIRef # Sets the target flow rate of discharge water
396 )
397 Discharge_Water_Temperature_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with temperature of the discharge water.
398 Discharge_Water_Temperature_Proportional_Band_Parameter: URIRef
399 Discharge_Water_Temperature_Sensor: (
400 URIRef # Measures the temperature of discharge water
401 )
402 Discharge_Water_Temperature_Setpoint: URIRef # Sets temperature of discharge water
403 Disconnect_Switch: URIRef # Building power is most commonly provided by utility company through a master disconnect switch (sometimes called a service disconnect) in the main electrical room of a building. The Utility Company provided master disconnect switch often owns or restricts access to this switch. There can also be other cases where a disconnect is placed into an electrical system to allow service cut-off to a portion of the building.
404 Displacement_Flow_Air_Diffuser: URIRef # An air diffuser that is designed for low discharge air speeds to minimize turbulence and induction of room air. This diffuser is used with displacement ventilation systems.
405 Distribution_Frame: URIRef # A class of spaces where the cables carrying signals meet and connect, e.g. a wiring closet or a broadcast downlink room
406 Domestic_Hot_Water_Supply_Temperature_Sensor: URIRef # Measures the temperature of domestic water supplied by a hot water system
407 Domestic_Hot_Water_Supply_Temperature_Setpoint: (
408 URIRef # Sets temperature of supplying part of domestic hot water
409 )
410 Domestic_Hot_Water_System: URIRef # The equipment, devices and conduits that handle the production and distribution of domestic hot water in a building
411 Domestic_Hot_Water_System_Enable_Command: (
412 URIRef # Enables operation of the domestic hot water system
413 )
414 Domestic_Hot_Water_Temperature_Setpoint: (
415 URIRef # Sets temperature of domestic hot water
416 )
417 Domestic_Hot_Water_Valve: (
418 URIRef # A valve regulating the flow of domestic hot water
419 )
420 Domestic_Water: (
421 URIRef # Tap water for drinking, washing, cooking, and flushing of toliets
422 )
423 Domestic_Water_Loop: URIRef
424 Drench_Hose: URIRef
425 Drive_Ready_Status: URIRef # Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID
426 Duration_Sensor: URIRef # Measures the duration of a phenomenon or event
427 ESS_Panel: URIRef # See Embedded_Surface_System_Panel
428 EconCycle_Start_Stop_Status: URIRef
429 Economizer: URIRef # Device that, on proper variable sensing, initiates control signals or actions to conserve energy. A control system that reduces the mechanical heating and cooling requirement.
430 Economizer_Damper: URIRef # A damper that is part of an economizer that is used to module the flow of air
431 Effective_Air_Temperature_Cooling_Setpoint: URIRef
432 Effective_Air_Temperature_Heating_Setpoint: URIRef
433 Effective_Air_Temperature_Setpoint: URIRef
434 Effective_Discharge_Air_Temperature_Setpoint: URIRef
435 Effective_Return_Air_Temperature_Setpoint: URIRef
436 Effective_Room_Air_Temperature_Setpoint: URIRef
437 Effective_Supply_Air_Temperature_Setpoint: URIRef
438 Effective_Zone_Air_Temperature_Setpoint: URIRef
439 Electric_Baseboard_Radiator: (
440 URIRef # Electric heating device located at or near the floor
441 )
442 Electric_Boiler: URIRef # A closed, pressure vessel that uses electricity for heating water or other fluids to supply steam or hot water for heating, humidification, or other applications.
443 Electric_Radiator: URIRef # Electric heating device
444 Electrical_Equipment: URIRef
445 Electrical_Meter: (
446 URIRef # A meter that measures the usage or consumption of electricity
447 )
448 Electrical_Power_Sensor: (
449 URIRef # Measures the amount of instantaneous electric power consumed
450 )
451 Electrical_Room: URIRef # A class of service rooms that house electrical equipment for a building
452 Electrical_System: URIRef # Devices that serve or are part of the electrical subsystem in the building
453 Elevator: URIRef # A device that provides vertical transportation between floors, levels or decks of a building, vessel or other structure
454 Elevator_Shaft: (
455 URIRef # The vertical space in which an elevator ascends and descends
456 )
457 Elevator_Space: (
458 URIRef # The vertical space in which an elevator ascends and descends
459 )
460 Embedded_Surface_System_Panel: URIRef # Radiant panel heating and cooling system where the energy heat source or sink is embedded in a radiant layer which is thermally insulated from the building structure.
461 Embedded_Temperature_Sensor: URIRef # Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system.
462 Embedded_Temperature_Setpoint: URIRef # Sets temperature for the internal material, e.g. concrete slab, of the radiant panel.
463 Emergency_Air_Flow_System: URIRef
464 Emergency_Air_Flow_System_Status: URIRef
465 Emergency_Alarm: URIRef # Alarms that indicate off-normal conditions associated with emergency systems
466 Emergency_Generator_Alarm: URIRef # An alarm that indicates off-normal conditions associated with an emergency generator
467 Emergency_Generator_Status: URIRef # Indicates if an emergency generator is active
468 Emergency_Phone: URIRef
469 Emergency_Power_Off_System: URIRef # A system that can power down a single piece of equipment or a single system from a single point
470 Emergency_Power_Off_System_Activated_By_High_Temperature_Status: URIRef
471 Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status: URIRef
472 Emergency_Power_Off_System_Status: URIRef
473 Emergency_Push_Button_Status: (
474 URIRef # Indicates if an emergency button has been pushed
475 )
476 Emergency_Wash_Station: URIRef
477 Employee_Entrance_Lobby: URIRef # An open space near an entrance that is typically only used for employees
478 Enable_Command: URIRef # Commands that enable functionality
479 Enable_Differential_Enthalpy_Command: (
480 URIRef # Enables the use of differential enthalpy control
481 )
482 Enable_Differential_Temperature_Command: (
483 URIRef # Enables the use of differential temperature control
484 )
485 Enable_Fixed_Enthalpy_Command: URIRef # Enables the use of fixed enthalpy control
486 Enable_Fixed_Temperature_Command: (
487 URIRef # Enables the use of fixed temperature control
488 )
489 Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint: URIRef # Enables hot water system when outside air temperature reaches the indicated value
490 Enable_Status: (
491 URIRef # Indicates if a system or piece of functionality has been enabled
492 )
493 Enclosed_Office: URIRef # A space for individuals to work with walls and a door
494 Energy_Generation_System: (
495 URIRef # A collection of devices that generates electricity
496 )
497 Energy_Sensor: URIRef # Measures energy consumption
498 Energy_Storage: (
499 URIRef # Devices or equipment that store energy in its various forms
500 )
501 Energy_Storage_System: URIRef # A collection of devices that stores electricity
502 Energy_System: URIRef # A collection of devices that generates, stores or transports electricity
503 Energy_Usage_Sensor: (
504 URIRef # Measures the total amount of energy used over some period of time
505 )
506 Energy_Zone: URIRef # A space or group of spaces that are managed or monitored as one unit for energy purposes
507 Entering_Water: URIRef # Water that is entering a piece of equipment or system
508 Entering_Water_Flow_Sensor: URIRef # Measures the rate of flow of water entering a piece of equipment or system
509 Entering_Water_Flow_Setpoint: URIRef # Sets the target flow rate of entering water
510 Entering_Water_Temperature_Sensor: URIRef # Measures the temperature of water entering a piece of equipment or system
511 Entering_Water_Temperature_Setpoint: URIRef # Sets temperature of entering water
512 Enthalpy_Sensor: URIRef # Measures the total heat content of some substance
513 Enthalpy_Setpoint: URIRef # Sets enthalpy
514 Entrance: URIRef # The location and space of a building where people enter and exit the building
515 Environment_Box: URIRef # (also known as climatic chamber), enclosed space designed to create a particular environment.
516 Equipment: URIRef # devices that serve all or part of the building and may include electric power, lighting, transportation, or service water heating, including, but not limited to, furnaces, boilers, air conditioners, heat pumps, chillers, water heaters, lamps, luminaires, ballasts, elevators, escalators, or other devices or installations.
517 Equipment_Room: URIRef # A telecommunications room where equipment that serves the building is stored
518 Evaporative_Heat_Exchanger: URIRef
519 Even_Month_Status: URIRef
520 Exercise_Room: URIRef # An indoor room used for exercise and physical activities
521 Exhaust_Air: URIRef # air that must be removed from a space due to contaminants, regardless of pressurization
522 Exhaust_Air_Dewpoint_Sensor: URIRef # Measures dewpoint of exhaust air
523 Exhaust_Air_Differential_Pressure_Sensor: URIRef # Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building
524 Exhaust_Air_Differential_Pressure_Setpoint: URIRef # Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit
525 Exhaust_Air_Flow_Integral_Time_Parameter: URIRef
526 Exhaust_Air_Flow_Proportional_Band_Parameter: URIRef
527 Exhaust_Air_Flow_Sensor: URIRef # Measures the rate of flow of exhaust air
528 Exhaust_Air_Flow_Setpoint: URIRef # Sets exhaust air flow rate
529 Exhaust_Air_Humidity_Sensor: URIRef # Measures the relative humidity of exhaust air
530 Exhaust_Air_Humidity_Setpoint: URIRef # Humidity setpoint for exhaust air
531 Exhaust_Air_Stack_Flow_Deadband_Setpoint: (
532 URIRef # Sets the size of a deadband of exhaust air stack flow
533 )
534 Exhaust_Air_Stack_Flow_Integral_Time_Parameter: URIRef
535 Exhaust_Air_Stack_Flow_Proportional_Band_Parameter: URIRef
536 Exhaust_Air_Stack_Flow_Sensor: (
537 URIRef # Measures the rate of flow of air in the exhaust air stack
538 )
539 Exhaust_Air_Stack_Flow_Setpoint: URIRef # Sets exhaust air stack flow rate
540 Exhaust_Air_Static_Pressure_Proportional_Band_Parameter: URIRef
541 Exhaust_Air_Static_Pressure_Sensor: (
542 URIRef # The static pressure of air within exhaust regions of an HVAC system
543 )
544 Exhaust_Air_Static_Pressure_Setpoint: URIRef # Sets static pressure of exhaust air
545 Exhaust_Air_Temperature_Sensor: URIRef # Measures the temperature of exhaust air
546 Exhaust_Air_Velocity_Pressure_Sensor: URIRef
547 Exhaust_Damper: URIRef # A damper that modulates the flow of exhaust air
548 Exhaust_Fan: URIRef # Fan moving exhaust air -- air that must be removed from a space due to contaminants
549 Exhaust_Fan_Disable_Command: URIRef # Disables operation of the exhaust fan
550 Exhaust_Fan_Enable_Command: URIRef # Enables operation of the exhaust fan
551 Eye_Wash_Station: URIRef
552 FCU: URIRef # See Fan_Coil_Unit
553 Failure_Alarm: URIRef # Alarms that indicate the failure of devices, equipment, systems and control loops
554 Fan: URIRef # Any device with two or more blades or vanes attached to a rotating shaft used to produce an airflow for the purpose of comfort, ventilation, exhaust, heating, cooling, or any other gaseous transport.
555 Fan_Coil_Unit: URIRef # Terminal device consisting of a heating and/or cooling heat exchanger or 'coil' and fan that is used to control the temperature in the space where it is installed
556 Fan_On_Off_Status: URIRef
557 Fan_Status: URIRef # Indicates properties of fans
558 Fan_VFD: URIRef # Variable-frequency drive for fans
559 Fault_Reset_Command: URIRef # Clears a fault status
560 Fault_Status: (
561 URIRef # Indicates the presence of a fault in a device, system or control loop
562 )
563 Field_Of_Play: URIRef # The area of a stadium where athletic events occur, e.g. the soccer pitch
564 Filter: URIRef # Device to remove gases from a mixture of gases or to remove solid material from a fluid
565 Filter_Differential_Pressure_Sensor: (
566 URIRef # Measures the difference in pressure on either side of a filter
567 )
568 Filter_Reset_Command: URIRef
569 Filter_Status: URIRef # Indicates if a filter needs to be replaced
570 Final_Filter: URIRef # The last, high-efficiency filter installed in a sequence to remove the finest particulates from the substance being filtered
571 Fire_Control_Panel: URIRef # A panel-mounted device that provides status and control of a fire safety system
572 Fire_Safety_Equipment: URIRef
573 Fire_Safety_System: URIRef # A system containing devices and equipment that monitor, detect and suppress fire hazards
574 Fire_Sensor: URIRef # Measures the presence of fire
575 Fire_Zone: URIRef # combustion chamber in a furnace or boiler.
576 First_Aid_Kit: URIRef
577 First_Aid_Room: URIRef # A room for a person with minor injuries can be treated or temporarily treated until transferred to a more advanced medical facility
578 Floor: URIRef # A level, typically representing a horizontal aggregation of spaces that are vertically bound. (referring to IFC)
579 Flow_Sensor: URIRef # Measures the rate of flow of some substance
580 Flow_Setpoint: URIRef # Sets flow
581 Fluid: URIRef # substance, as a liquid or gas, that is capable of flowing and that changes shape when acted on by a force.
582 Food_Service_Room: URIRef # A space used in the production, storage, serving, or cleanup of food and beverages
583 Formaldehyde_Level_Sensor: (
584 URIRef # Measures the concentration of formaldehyde in air
585 )
586 Freeze_Status: (
587 URIRef # Indicates if a substance contained within a vessel has frozen
588 )
589 Freezer: URIRef # cold chamber usually kept at a temperature of 22°F to 31°F (–5°C to –1°C), with high-volume air circulation.
590 Frequency_Command: URIRef # Controls the frequency of a device's operation (e.g. rotational frequency)
591 Frequency_Sensor: URIRef # Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning
592 Fresh_Air_Fan: URIRef # Fan moving fresh air -- air that is supplied into the building from the outdoors
593 Fresh_Air_Setpoint_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint.
594 Frost: URIRef # frost formed on the cold surface (tubes, plates) of a cooling coil.
595 Frost_Sensor: (
596 URIRef # Senses the presence of frost or conditions that may cause frost
597 )
598 Fuel_Oil: URIRef # Petroleum based oil burned for energy
599 Fume_Hood: URIRef # A fume-collection device mounted over a work space, table, or shelf and serving to conduct unwanted gases away from the area enclosed.
600 Fume_Hood_Air_Flow_Sensor: URIRef # Measures the rate of flow of air in a fume hood
601 Furniture: URIRef # Movable objects intended to support various human activities such as seating, eating and sleeping
602 Gain_Parameter: URIRef
603 Gas: URIRef # state of matter in which substances exist in the form of nonaggregated molecules and which, within acceptable limits of accuracy, satisfy the ideal gas laws; usually a highly superheated vapor. See [[state]].
604 Gas_Distribution: URIRef # Utilize a gas distribution source to represent how gas is distributed across multiple destinations
605 Gas_Meter: URIRef # A meter that measures the usage or consumption of gas
606 Gas_Sensor: URIRef # Measures gas concentration (other than CO2)
607 Gas_System: URIRef
608 Gas_Valve: URIRef
609 Gasoline: URIRef # Petroleum derived liquid used as a fuel source
610 Gatehouse: URIRef # The standalone building used to manage the entrance to a campus or building grounds
611 Generator_Room: (
612 URIRef # A room for electrical equipment, specifically electrical generators.
613 )
614 Glycol: URIRef
615 HVAC_Equipment: URIRef # See Heating_Ventilation_Air_Conditioning_System
616 HVAC_System: URIRef # See Heating_Ventilation_Air_Conditioning_System
617 HVAC_Zone: URIRef # a space or group of spaces, within a building with heating, cooling, and ventilating requirements, that are sufficiently similar so that desired conditions (e.g., temperature) can be maintained throughout using a single sensor (e.g., thermostat or temperature sensor).
618 HX: URIRef # See Heat_Exchanger
619 Hail: (
620 URIRef # pellets of frozen rain which fall in showers from cumulonimbus clouds.
621 )
622 Hail_Sensor: URIRef # Measures hail in terms of its size and damage potential
623 Hallway: URIRef # A common space, used to connect other parts of a building
624 Hazardous_Materials_Storage: URIRef # A storage space set aside (usually with restricted access) for the storage of materials that can be hazardous to living beings or the environment
625 Heat_Exchanger: URIRef # A heat exchanger is a piece of equipment built for efficient heat transfer from one medium to another. The media may be separated by a solid wall to prevent mixing or they may be in direct contact (BEDES)
626 Heat_Exchanger_Supply_Water_Temperature_Sensor: (
627 URIRef # Measures the temperature of water supplied by a heat exchanger
628 )
629 Heat_Exchanger_System_Enable_Status: (
630 URIRef # Indicates if the heat exchanger system has been enabled
631 )
632 Heat_Recovery_Hot_Water_System: URIRef
633 Heat_Sensor: URIRef # Measures heat
634 Heat_Wheel: URIRef # A rotary heat exchanger positioned within the supply and exhaust air streams of an air handling system in order to recover heat energy
635 Heat_Wheel_VFD: URIRef # A VFD that drives a heat wheel
636 Heating_Coil: URIRef # A heating element typically made of pipe, tube or wire that emits heat. Typically filled with hot water, or, in the case of wire, uses electricity.
637 Heating_Command: URIRef # Controls the amount of heating to be delivered (typically as a proportion of total heating output)
638 Heating_Demand_Sensor: URIRef # Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton
639 Heating_Demand_Setpoint: URIRef # Sets the rate required for heating
640 Heating_Discharge_Air_Flow_Setpoint: URIRef # Sets discharge air flow for heating
641 Heating_Discharge_Air_Temperature_Deadband_Setpoint: (
642 URIRef # Sets the size of a deadband of temperature of heating discharge air
643 )
644 Heating_Discharge_Air_Temperature_Integral_Time_Parameter: URIRef
645 Heating_Discharge_Air_Temperature_Proportional_Band_Parameter: URIRef
646 Heating_Start_Stop_Status: URIRef
647 Heating_Supply_Air_Flow_Setpoint: URIRef # Sets supply air flow rate for heating
648 Heating_Supply_Air_Temperature_Deadband_Setpoint: (
649 URIRef # Sets the size of a deadband of temperature of supply air for heating
650 )
651 Heating_Supply_Air_Temperature_Integral_Time_Parameter: URIRef
652 Heating_Supply_Air_Temperature_Proportional_Band_Parameter: URIRef
653 Heating_Temperature_Setpoint: URIRef # Sets temperature for heating
654 Heating_Thermal_Power_Sensor: URIRef
655 Heating_Valve: URIRef # A valve that controls air temperature by modulating the amount of hot water flowing through a heating coil
656 Heating_Ventilation_Air_Conditioning_System: URIRef # The equipment, distribution systems and terminals that provide, either collectively or individually, the processes of heating, ventilating or air conditioning to a building or portion of a building
657 High_CO2_Alarm: (
658 URIRef # A device that indicates high concentration of carbon dioxide.
659 )
660 High_Discharge_Air_Temperature_Alarm: (
661 URIRef # An alarm that indicates that discharge air temperature is too high
662 )
663 High_Head_Pressure_Alarm: URIRef # An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system.
664 High_Humidity_Alarm: (
665 URIRef # An alarm that indicates high concentration of water vapor in the air.
666 )
667 High_Humidity_Alarm_Parameter: URIRef # A parameter determining the humidity level at which to trigger a high humidity alarm
668 High_Outside_Air_Lockout_Temperature_Differential_Parameter: (
669 URIRef # The upper bound of the outside air temperature lockout range
670 )
671 High_Return_Air_Temperature_Alarm: (
672 URIRef # An alarm that indicates that return air temperature is too high
673 )
674 High_Static_Pressure_Cutout_Setpoint_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint.
675 High_Temperature_Alarm: URIRef # An alarm that indicates high temperature.
676 High_Temperature_Alarm_Parameter: URIRef # A parameter determining the temperature level at which to trigger a high temperature alarm
677 High_Temperature_Hot_Water_Return_Temperature_Sensor: URIRef # Measures the temperature of high-temperature hot water returned to a hot water system
678 High_Temperature_Hot_Water_Supply_Temperature_Sensor: URIRef # Measures the temperature of high-temperature hot water supplied by a hot water system
679 Hold_Status: URIRef
680 Hospitality_Box: URIRef # A room at a stadium, usually overlooking the field of play, that is physical separate from the other seating at the venue
681 Hot_Box: URIRef # hot air chamber forming part of an air handler.
682 Hot_Water: URIRef # Hot water used for HVAC heating or supply to hot taps
683 Hot_Water_Baseboard_Radiator: (
684 URIRef # Hydronic heating device located at or near the floor
685 )
686 Hot_Water_Coil: URIRef # A heating element typically made of pipe, tube or wire that emits heat that is filled with hot water.
687 Hot_Water_Differential_Pressure_Deadband_Setpoint: (
688 URIRef # Sets the size of a deadband of differential pressure of hot water
689 )
690 Hot_Water_Differential_Pressure_Integral_Time_Parameter: URIRef
691 Hot_Water_Differential_Pressure_Load_Shed_Reset_Status: URIRef
692 Hot_Water_Differential_Pressure_Load_Shed_Status: URIRef
693 Hot_Water_Differential_Pressure_Proportional_Band_Parameter: URIRef
694 Hot_Water_Differential_Pressure_Sensor: URIRef # Measures the difference in water pressure on either side of a hot water valve
695 Hot_Water_Differential_Pressure_Setpoint: URIRef # Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water
696 Hot_Water_Differential_Temperature_Sensor: URIRef # Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device
697 Hot_Water_Discharge_Flow_Sensor: (
698 URIRef # Measures the rate of flow of hot discharge water
699 )
700 Hot_Water_Discharge_Flow_Setpoint: (
701 URIRef # Sets the target flow rate of hot discharge water
702 )
703 Hot_Water_Discharge_Temperature_Load_Shed_Status: URIRef
704 Hot_Water_Flow_Sensor: URIRef # Measures the rate of flow in a hot water circuit
705 Hot_Water_Flow_Setpoint: URIRef # Sets the target flow rate of hot water
706 Hot_Water_Loop: URIRef # A collection of equipment that transport and regulate hot water among each other
707 Hot_Water_Meter: (
708 URIRef # A meter that measures the usage or consumption of hot water
709 )
710 Hot_Water_Pump: URIRef # A pump that performs work on hot water; typically part of a hot water system
711 Hot_Water_Radiator: URIRef # Radiator that uses hot water
712 Hot_Water_Return_Flow_Sensor: (
713 URIRef # Measures the rate of flow of hot return water
714 )
715 Hot_Water_Return_Temperature_Sensor: (
716 URIRef # Measures the temperature of water returned to a hot water system
717 )
718 Hot_Water_Static_Pressure_Setpoint: URIRef # Sets static pressure of hot air
719 Hot_Water_Supply_Flow_Sensor: (
720 URIRef # Measures the rate of flow of hot supply water
721 )
722 Hot_Water_Supply_Flow_Setpoint: (
723 URIRef # Sets the target flow rate of hot supply water
724 )
725 Hot_Water_Supply_Temperature_High_Reset_Setpoint: URIRef
726 Hot_Water_Supply_Temperature_Load_Shed_Status: URIRef
727 Hot_Water_Supply_Temperature_Low_Reset_Setpoint: URIRef
728 Hot_Water_Supply_Temperature_Sensor: (
729 URIRef # Measures the temperature of water supplied by a hot water system
730 )
731 Hot_Water_System: URIRef # The equipment, devices and conduits that handle the production and distribution of hot water in a building
732 Hot_Water_System_Enable_Command: URIRef # Enables operation of the hot water system
733 Hot_Water_Temperature_Setpoint: URIRef # Sets the temperature of hot water
734 Hot_Water_Usage_Sensor: URIRef # Measures the amount of hot water that is consumed, over some period of time
735 Hot_Water_Valve: URIRef # A valve regulating the flow of hot water
736 Humidification_Start_Stop_Status: URIRef
737 Humidifier: URIRef # A device that adds moisture to air or other gases
738 Humidifier_Fault_Status: URIRef # Indicates the presence of a fault in a humidifier
739 Humidify_Command: URIRef
740 Humidity_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air.
741 Humidity_Parameter: (
742 URIRef # Parameters relevant to humidity-related systems and points
743 )
744 Humidity_Sensor: URIRef # Measures the concentration of water vapor in air
745 Humidity_Setpoint: URIRef # Sets humidity
746 Humidity_Tolerance_Parameter: URIRef # A parameter determining the difference between upper and lower limits of humidity.
747 IDF: URIRef # An room for an intermediate distribution frame, where cables carrying signals from the main distribution frame terminate and then feed out to endpoints
748 Ice: URIRef # Water in its solid form
749 Ice_Tank_Leaving_Water_Temperature_Sensor: (
750 URIRef # Measures the temperature of water leaving an ice tank
751 )
752 Illuminance_Sensor: (
753 URIRef # Measures the total luminous flux incident on a surface, per unit area
754 )
755 Imbalance_Sensor: URIRef # A sensor which measures difference (imbalance) between phases of an electrical system
756 Induction_Unit: URIRef # A device with an primary air connection and integrated coil and condensate pan that performs sensible and latent cooling of a space. Essentially an Active Chilled Beam with a built in condensate pan.
757 Information_Area: URIRef # An information booth or kiosk where visitors would look for information
758 Inside_Face_Surface_Temperature_Sensor: URIRef # Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system.
759 Inside_Face_Surface_Temperature_Setpoint: URIRef # Sets temperature for the inside face surface temperature of the radiant panel.
760 Intake_Air_Filter: URIRef # Filters air intake
761 Intake_Air_Temperature_Sensor: (
762 URIRef # Measures air at the interface between the building and the outside
763 )
764 Integral_Gain_Parameter: URIRef
765 Integral_Time_Parameter: URIRef
766 Intercom_Equipment: URIRef
767 Interface: (
768 URIRef # A device that provides an occupant control over a lighting system
769 )
770 Intrusion_Detection_Equipment: URIRef
771 Inverter: URIRef # A device that changes direct current into alternating current
772 Isolation_Valve: URIRef # A valve that stops the flow of a fluid, usually for maintenance or safety purposes
773 Janitor_Room: (
774 URIRef # A room set aside for the storage of cleaning equipment and supplies
775 )
776 Jet_Nozzle_Air_Diffuser: URIRef # An air diffuser that is designed to produce high velocity discharge air stream to throw the air over a large distance or target the air stream to a localize area
777 Laboratory: URIRef # facility acceptable to the local, national, or international recognized authority having jurisdiction and which provides uniform testing and examination procedures and standards for meeting design, manufacturing, and factory testing requirements.
778 Laminar_Flow_Air_Diffuser: URIRef # An air diffuser that is designed for low discharge air speeds to provide uniform and unidirectional air pattern which minimizes room air entrainment
779 Last_Fault_Code_Status: URIRef # Indicates the last fault code that occurred
780 Lead_Lag_Command: URIRef # Enables lead/lag operation
781 Lead_Lag_Status: URIRef # Indicates if lead/lag operation is enabled
782 Lead_On_Off_Command: URIRef # Controls the active/inactive status of the "lead" part of a lead/lag system
783 Leak_Alarm: (
784 URIRef # An alarm that indicates leaks occurred in systems containing fluids
785 )
786 Leaving_Water: URIRef # Water that is leaving a piece of equipment or system
787 Leaving_Water_Flow_Sensor: URIRef # Measures the rate of flow of water that is leaving a piece of equipment or system
788 Leaving_Water_Flow_Setpoint: URIRef # Sets the target flow rate of leaving water
789 Leaving_Water_Temperature_Sensor: URIRef # Measures the temperature of water leaving a piece of equipment or system
790 Leaving_Water_Temperature_Setpoint: URIRef # Sets temperature of leaving water
791 Library: URIRef # A place for the storage and/or consumption of physical media, e.g. books, periodicals, and DVDs/CDs
792 Lighting: URIRef
793 Lighting_Equipment: URIRef
794 Lighting_System: URIRef # The equipment, devices and interfaces that serve or are a part of the lighting subsystem in a building
795 Lighting_Zone: URIRef
796 Limit: URIRef # A parameter that places an upper or lower bound on the range of permitted values of another point
797 Liquid: URIRef # state of matter intermediate between crystalline substances and gases in which the volume of a substance, but not the shape, remains relatively constant.
798 Liquid_CO2: URIRef # Carbon Dioxide in the liquid phase
799 Liquid_Detection_Alarm: URIRef
800 Load_Current_Sensor: URIRef # Measures the current consumed by a load
801 Load_Parameter: URIRef
802 Load_Setpoint: URIRef
803 Load_Shed_Command: (
804 URIRef # Controls load shedding behavior provided by a control system
805 )
806 Load_Shed_Differential_Pressure_Setpoint: URIRef
807 Load_Shed_Setpoint: URIRef
808 Load_Shed_Status: URIRef # Indicates if a load shedding policy is in effect
809 Loading_Dock: URIRef # A part of a facility where delivery trucks can load and unload. Usually partially enclosed with specific traffic lanes leading to the dock
810 Lobby: URIRef # A space just after the entrance to a building or other space of a building, where visitors can wait
811 Locally_On_Off_Status: URIRef
812 Location: URIRef
813 Lockout_Status: URIRef # Indicates if a piece of equipment, system, or functionality has been locked out from operation
814 Lockout_Temperature_Differential_Parameter: URIRef
815 Loop: URIRef # A collection of connected equipment; part of a System
816 Lounge: URIRef # A room for lesiure activities or relaxing
817 Louver: URIRef # Device consisting of an assembly of parallel sloping vanes, intended to permit the passage of air while providing a measure of protection against environmental influences
818 Low_Freeze_Protect_Temperature_Parameter: URIRef
819 Low_Humidity_Alarm: (
820 URIRef # An alarm that indicates low concentration of water vapor in the air.
821 )
822 Low_Humidity_Alarm_Parameter: URIRef # A parameter determining the humidity level at which to trigger a low humidity alarm
823 Low_Outside_Air_Lockout_Temperature_Differential_Parameter: (
824 URIRef # The lower bound of the outside air temperature lockout range
825 )
826 Low_Outside_Air_Temperature_Enable_Differential_Sensor: URIRef
827 Low_Outside_Air_Temperature_Enable_Setpoint: URIRef
828 Low_Return_Air_Temperature_Alarm: (
829 URIRef # An alarm that indicates that return air temperature is too low
830 )
831 Low_Suction_Pressure_Alarm: URIRef # An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system.
832 Low_Temperature_Alarm: URIRef # An alarm that indicates low temperature.
833 Low_Temperature_Alarm_Parameter: URIRef # A parameter determining the temperature level at which to trigger a low temperature alarm
834 Lowest_Exhaust_Air_Static_Pressure_Sensor: URIRef # The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time
835 Luminaire: URIRef # A complete lighting unit consisting of a lamp or lamps and ballast(s) (when applicable) together with the parts designed to distribute the light, to position and protect the lamps, and to connect the lamps to the power supply.
836 Luminaire_Driver: URIRef # A power source for a luminaire
837 Luminance_Alarm: URIRef
838 Luminance_Command: (
839 URIRef # Controls the amount of luminance delivered by a lighting system
840 )
841 Luminance_Sensor: URIRef # Measures the luminous intensity per unit area of light travelling in a given direction
842 Luminance_Setpoint: URIRef # Sets luminance
843 MAU: URIRef # See Makeup_Air_Unit
844 MDF: URIRef # A room for the Main Distribution Frame, the central place of a building where cables carrying signals meet and connect to the outside world
845 Mail_Room: URIRef # A room where mail is received and sorted for distribution to the rest of the building
846 Maintenance_Mode_Command: URIRef # Controls whether or not a device or controller is operating in "Maintenance" mode
847 Maintenance_Required_Alarm: URIRef # An alarm that indicates that repair/maintenance is required on an associated device or equipment
848 Majlis: URIRef # In Arab countries, an Majlis is a private lounge where visitors are received and entertained
849 Makeup_Air_Unit: URIRef # A device designed to condition ventilation air introduced into a space or to replace air exhausted from a process or general area exhaust. The device may be used to prevent negative pressure within buildings or to reduce airborne contaminants in a space.
850 Makeup_Water: URIRef # Water used used to makeup water loss through leaks, evaporation, or blowdown
851 Makeup_Water_Valve: URIRef # A valve regulating the flow of makeup water into a water holding tank, e.g. a cooling tower, hot water tank
852 Manual_Auto_Status: (
853 URIRef # Indicates if a system is under manual or automatic operation
854 )
855 Massage_Room: URIRef # Usually adjunct to an athletic facility, a private/semi-private space where massages are performed
856 Max_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint.
857 Max_Air_Temperature_Setpoint: URIRef # Setpoint for maximum air temperature
858 Max_Chilled_Water_Differential_Pressure_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint.
859 Max_Cooling_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint.
860 Max_Cooling_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint.
861 Max_Discharge_Air_Static_Pressure_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint.
862 Max_Discharge_Air_Temperature_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint.
863 Max_Frequency_Command: URIRef # Sets the maximum permitted frequency
864 Max_Heating_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint.
865 Max_Heating_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint.
866 Max_Hot_Water_Differential_Pressure_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint.
867 Max_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Setpoint.
868 Max_Load_Setpoint: URIRef
869 Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint.
870 Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint.
871 Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint.
872 Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint.
873 Max_Position_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Position_Setpoint.
874 Max_Speed_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint.
875 Max_Static_Pressure_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint.
876 Max_Supply_Air_Static_Pressure_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint.
877 Max_Temperature_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint.
878 Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint.
879 Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint.
880 Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint.
881 Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint.
882 Max_Water_Level_Alarm: (
883 URIRef # Alarm indicating that the maximum water level was reached
884 )
885 Max_Water_Temperature_Setpoint: URIRef # Setpoint for max water temperature
886 Measurable: URIRef
887 Mechanical_Room: (
888 URIRef # A class of service rooms where mechanical equipment (HVAC) operates
889 )
890 Media_Hot_Desk: URIRef # A non-enclosed space used by members of the media temporarily to cover an event while they are present at a venue
891 Media_Production_Room: URIRef # A enclosed space used by media professionals for the production of media
892 Media_Room: URIRef # A class of spaces related to the creation of media
893 Medical_Room: URIRef # A class of rooms used for medical purposes
894 Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status: URIRef
895 Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint: URIRef
896 Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status: URIRef
897 Medium_Temperature_Hot_Water_Differential_Pressure_Sensor: URIRef # Measures the difference in water pressure between sections of a medium temperature hot water system
898 Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint: URIRef
899 Medium_Temperature_Hot_Water_Discharge_Temperature_High_Reset_Setpoint: URIRef
900 Medium_Temperature_Hot_Water_Discharge_Temperature_Low_Reset_Setpoint: URIRef
901 Medium_Temperature_Hot_Water_Return_Temperature_Sensor: URIRef # Measures the temperature of medium-temperature hot water returned to a hot water system
902 Medium_Temperature_Hot_Water_Supply_Temperature_High_Reset_Setpoint: URIRef
903 Medium_Temperature_Hot_Water_Supply_Temperature_Load_Shed_Setpoint: URIRef
904 Medium_Temperature_Hot_Water_Supply_Temperature_Load_Shed_Status: URIRef
905 Medium_Temperature_Hot_Water_Supply_Temperature_Low_Reset_Setpoint: URIRef
906 Medium_Temperature_Hot_Water_Supply_Temperature_Sensor: URIRef # Measures the temperature of medium-temperature hot water supplied by a hot water system
907 Meter: URIRef # A device that measure usage or consumption of some media --- typically a form energy or power.
908 Methane_Level_Sensor: URIRef # Measures the concentration of methane in air
909 Min_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint.
910 Min_Air_Temperature_Setpoint: URIRef # Setpoint for minimum air temperature
911 Min_Chilled_Water_Differential_Pressure_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint.
912 Min_Cooling_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Cooling_Discharge_Air_Flow_Setpoint.
913 Min_Cooling_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint.
914 Min_Discharge_Air_Static_Pressure_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Static_Pressure_Setpoint.
915 Min_Discharge_Air_Temperature_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Discharge_Air_Temperature_Setpoint.
916 Min_Fresh_Air_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint.
917 Min_Heating_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Heating_Discharge_Air_Flow_Setpoint.
918 Min_Heating_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint.
919 Min_Hot_Water_Differential_Pressure_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint.
920 Min_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Setpoint.
921 Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Discharge_Air_Flow_Setpoint.
922 Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint.
923 Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Discharge_Air_Flow_Setpoint.
924 Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint.
925 Min_Outside_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint.
926 Min_Position_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Position_Setpoint.
927 Min_Speed_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint.
928 Min_Static_Pressure_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint.
929 Min_Supply_Air_Static_Pressure_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint.
930 Min_Temperature_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint.
931 Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Discharge_Air_Flow_Setpoint.
932 Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint.
933 Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Discharge_Air_Flow_Setpoint.
934 Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit: URIRef # A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint.
935 Min_Water_Level_Alarm: (
936 URIRef # Alarm indicating that the minimum water level was reached
937 )
938 Min_Water_Temperature_Setpoint: URIRef # Setpoint for min water temperature
939 Mixed_Air: URIRef # (1) air that contains two or more streams of air. (2) combined outdoor air and recirculated air.
940 Mixed_Air_Filter: URIRef # A filter that is applied to the mixture of recirculated and outside air
941 Mixed_Air_Flow_Sensor: URIRef # Measures the rate of flow of mixed air
942 Mixed_Air_Humidity_Sensor: URIRef # Measures the humidity of mixed air
943 Mixed_Air_Humidity_Setpoint: URIRef # Humidity setpoint for mixed air
944 Mixed_Air_Temperature_Sensor: URIRef # Measures the temperature of mixed air
945 Mixed_Air_Temperature_Setpoint: URIRef # Sets temperature of mixed air
946 Mixed_Damper: URIRef # A damper that modulates the flow of the mixed outside and return air streams
947 Mode_Command: URIRef # Controls the operating mode of a device or controller
948 Mode_Status: (
949 URIRef # Indicates which mode a system, device or control loop is currently in
950 )
951 Motion_Sensor: URIRef # Detects the presence of motion in some area
952 Motor: URIRef # A machine in which power is applied to do work by the conversion of various forms of energy into mechanical force and motion.
953 Motor_Control_Center: URIRef # The Motor Control Center is a specialized type of switchgear which provides electrical power to major mechanical systems in the building such as HVAC components.
954 Motor_Current_Sensor: URIRef # Measures the current consumed by a motor
955 Motor_Direction_Status: URIRef # Indicates which direction a motor is operating in, e.g. forward or reverse
956 Motor_On_Off_Status: URIRef
957 Motor_Speed_Sensor: URIRef
958 Motor_Torque_Sensor: URIRef # Measures the torque, or rotating power, of a motor
959 NO2_Level_Sensor: URIRef # Measures the concentration of NO2 in air
960 NVR: URIRef
961 Natural_Gas: URIRef # Fossil fuel energy source consisting largely of methane and other hydrocarbons
962 Natural_Gas_Boiler: URIRef # A closed, pressure vessel that uses natural gas for heating water or other fluids to supply steam or hot water for heating, humidification, or other applications.
963 Network_Video_Recorder: URIRef
964 No_Water_Alarm: (
965 URIRef # Alarm indicating that there is no water in the equipment or system
966 )
967 Noncondensing_Natural_Gas_Boiler: URIRef # A closed, pressure vessel that uses natural gas with no system to capture latent heat for heating water or other fluids to supply steam or hot water for heating, humidification, or other applications.
968 Occupancy_Command: URIRef # Controls whether or not a device or controller is operating in "Occupied" mode
969 Occupancy_Sensor: URIRef # Detects occupancy of some space or area
970 Occupancy_Status: URIRef # Indicates if a room or space is occupied
971 Occupied_Air_Temperature_Setpoint: URIRef
972 Occupied_Cooling_Discharge_Air_Flow_Setpoint: (
973 URIRef # Sets discharge air flow for cooling when occupied
974 )
975 Occupied_Cooling_Supply_Air_Flow_Setpoint: (
976 URIRef # Sets supply air flow rate for cooling when occupied
977 )
978 Occupied_Cooling_Temperature_Deadband_Setpoint: (
979 URIRef # Sets the size of a deadband of temperature for cooling when occupied
980 )
981 Occupied_Discharge_Air_Flow_Setpoint: (
982 URIRef # Sets discharge air flow when occupied
983 )
984 Occupied_Discharge_Air_Temperature_Setpoint: URIRef
985 Occupied_Heating_Discharge_Air_Flow_Setpoint: (
986 URIRef # Sets discharge air flow for heating when occupied
987 )
988 Occupied_Heating_Supply_Air_Flow_Setpoint: (
989 URIRef # Sets supply air flow rate for heating when occupied
990 )
991 Occupied_Heating_Temperature_Deadband_Setpoint: (
992 URIRef # Sets the size of a deadband of temperature for heating when occupied
993 )
994 Occupied_Mode_Status: (
995 URIRef # Indicates if a system, device or control loop is in "Occupied" mode
996 )
997 Occupied_Return_Air_Temperature_Setpoint: URIRef
998 Occupied_Room_Air_Temperature_Setpoint: URIRef
999 Occupied_Supply_Air_Flow_Setpoint: URIRef # Sets supply air flow rate when occupied
1000 Occupied_Supply_Air_Temperature_Setpoint: URIRef
1001 Occupied_Zone_Air_Temperature_Setpoint: URIRef
1002 Off_Command: URIRef # An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'
1003 Off_Status: URIRef # Indicates if a control loop, relay or equipment is off
1004 Office: URIRef # A class of rooms dedicated for work or study
1005 Office_Kitchen: URIRef # A common space, usually near or in a breakroom, where minor food preparation occurs
1006 Oil: URIRef # a viscous liquid derived from petroleum, especially for use as a fuel or lubricant.
1007 On_Command: URIRef # An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'
1008 On_Off_Command: URIRef # An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity
1009 On_Off_Status: (
1010 URIRef # Indicates the on/off status of a control loop, relay or equipment
1011 )
1012 On_Status: URIRef # Indicates if a control loop, relay or equipment is on
1013 On_Timer_Sensor: URIRef # Measures the duration for which a device was in an active or "on" state
1014 Open_Close_Status: (
1015 URIRef # Indicates the open/close status of a device such as a damper or valve
1016 )
1017 Open_Heating_Valve_Outside_Air_Temperature_Setpoint: URIRef
1018 Open_Office: URIRef # An open space used for work or study by multiple people. Usuaully subdivided into cubicles or desks
1019 Operating_Mode_Status: URIRef # Indicates the current operating mode of a system, device or control loop
1020 Outdoor_Area: URIRef # A class of spaces that exist outside of a building
1021 Output_Frequency_Sensor: URIRef
1022 Output_Voltage_Sensor: (
1023 URIRef # Measures the voltage output by some process or device
1024 )
1025 Outside: URIRef
1026 Outside_Air: URIRef # air external to a defined zone (e.g., corridors).
1027 Outside_Air_CO2_Sensor: URIRef # Measures the concentration of CO2 in outside air
1028 Outside_Air_CO_Sensor: URIRef # Measures the concentration of CO in outside air
1029 Outside_Air_Dewpoint_Sensor: (
1030 URIRef # Senses the dewpoint temperature of outside air
1031 )
1032 Outside_Air_Enthalpy_Sensor: (
1033 URIRef # Measures the total heat content of outside air
1034 )
1035 Outside_Air_Flow_Sensor: (
1036 URIRef # Measures the rate of flow of outside air into the system
1037 )
1038 Outside_Air_Flow_Setpoint: URIRef # Sets outside air flow rate
1039 Outside_Air_Grains_Sensor: URIRef # Measures the mass of water vapor in outside air
1040 Outside_Air_Humidity_Sensor: URIRef # Measures the relative humidity of outside air
1041 Outside_Air_Humidity_Setpoint: URIRef # Humidity setpoint for outside air
1042 Outside_Air_Lockout_Temperature_Differential_Parameter: URIRef
1043 Outside_Air_Lockout_Temperature_Setpoint: URIRef
1044 Outside_Air_Temperature_Enable_Differential_Sensor: URIRef
1045 Outside_Air_Temperature_High_Reset_Setpoint: URIRef
1046 Outside_Air_Temperature_Low_Reset_Setpoint: URIRef
1047 Outside_Air_Temperature_Sensor: URIRef # Measures the temperature of outside air
1048 Outside_Air_Temperature_Setpoint: URIRef # Sets temperature of outside air
1049 Outside_Air_Wet_Bulb_Temperature_Sensor: (
1050 URIRef # A sensor measuring the wet-bulb temperature of outside air
1051 )
1052 Outside_Damper: URIRef # A damper that modulates the flow of outside air
1053 Outside_Face_Surface_Temperature_Sensor: URIRef # Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system.
1054 Outside_Face_Surface_Temperature_Setpoint: URIRef # Sets temperature for the outside face surface temperature of the radiant panel.
1055 Outside_Illuminance_Sensor: (
1056 URIRef # Measures the total luminous flux incident on an outside, per unit area
1057 )
1058 Overload_Alarm: (
1059 URIRef # An alarm that can indicate when a full-load current is exceeded.
1060 )
1061 Overridden_Off_Status: URIRef # Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on
1062 Overridden_On_Status: URIRef # Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off
1063 Overridden_Status: URIRef # Indicates if the expected operating status of an equipment or control loop has been overridden
1064 Override_Command: URIRef # Controls or reports whether or not a device or control loop is in 'override'
1065 Ozone_Level_Sensor: URIRef # Measures the concentration of ozone in air
1066 PAU: URIRef # A type of AHU, use to pre-treat the outdoor air before feed to AHU
1067 PID_Parameter: URIRef
1068 PIR_Sensor: URIRef # Detects the presence of motion in some area using the differential change in infrared intensity between two or more receptors
1069 PM10_Level_Sensor: URIRef # Detects level of particulates of size 10 microns
1070 PM10_Sensor: URIRef # Detects matter of size 10 microns
1071 PM1_Level_Sensor: URIRef # Detects level of particulates of size 1 microns
1072 PM1_Sensor: URIRef # Detects matter of size 1 micron
1073 PVT_Panel: URIRef # A type of solar panels that convert solar radiation into usable thermal and electrical energy
1074 PV_Array: URIRef
1075 PV_Current_Output_Sensor: URIRef # See Photovoltaic_Current_Output_Sensor
1076 PV_Generation_System: (
1077 URIRef # A collection of photovoltaic devices that generates energy
1078 )
1079 PV_Panel: URIRef # An integrated assembly of interconnected photovoltaic cells designed to deliver a selected level of working voltage and current at its output terminals packaged for protection against environment degradation and suited for incorporation in photovoltaic power systems.
1080 Parameter: URIRef # Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values
1081 Parking_Level: URIRef # A floor of a parking structure
1082 Parking_Space: URIRef # An area large enough to park an individual vehicle
1083 Parking_Structure: (
1084 URIRef # A building or part of a building devoted to vehicle parking
1085 )
1086 Particulate_Matter_Sensor: URIRef # Detects pollutants in the ambient air
1087 Passive_Chilled_Beam: URIRef # A chilled beam that does not have an integral air supply and instead relies on natural convection to draw air through the device.
1088 Peak_Power_Demand_Sensor: (
1089 URIRef # The peak power consumed by a process over some period of time
1090 )
1091 Photovoltaic_Array: URIRef # A collection of photovoltaic panels
1092 Photovoltaic_Current_Output_Sensor: URIRef # Senses the amperes of electrical current produced as output by a photovoltaic device
1093 Piezoelectric_Sensor: URIRef # Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect
1094 PlugStrip: URIRef # A device containing a block of electrical sockets allowing multiple electrical devices to be powered from a single electrical socket.
1095 Plumbing_Room: URIRef # A service room devoted to the operation and routing of water in a building. Usually distinct from the HVAC subsystems.
1096 Point: URIRef
1097 Portfolio: URIRef # A collection of sites
1098 Position_Command: URIRef # Controls or reports the position of some object
1099 Position_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint.
1100 Position_Sensor: URIRef # Measures the current position of a component in terms of a fraction of its full range of motion
1101 Potable_Water: URIRef # Water that is safe to drink
1102 Power_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with electrical power.
1103 Power_Loss_Alarm: URIRef # An alarm that indicates a power failure.
1104 Power_Sensor: URIRef # Measures the amount of instantaneous power consumed
1105 Prayer_Room: URIRef # A room set aside for prayer
1106 Pre_Filter: URIRef # A filter installed in front of a more efficient filter to extend the life of the more expensive higher efficiency filter
1107 Pre_Filter_Status: URIRef # Indicates if a prefilter needs to be replaced
1108 Preheat_Demand_Setpoint: URIRef # Sets the rate required for preheat
1109 Preheat_Discharge_Air_Temperature_Sensor: (
1110 URIRef # Measures the temperature of discharge air before heating is applied
1111 )
1112 Preheat_Hot_Water_System: URIRef
1113 Preheat_Hot_Water_Valve: URIRef
1114 Preheat_Supply_Air_Temperature_Sensor: (
1115 URIRef # Measures the temperature of supply air before it is heated
1116 )
1117 Pressure_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with pressure.
1118 Pressure_Sensor: URIRef # Measure the amount of force acting on a unit area
1119 Pressure_Setpoint: URIRef # Sets pressure
1120 Pressure_Status: URIRef # Indicates if pressure is within expected bounds
1121 Private_Office: (
1122 URIRef # An office devoted to a single individual, with walls and door
1123 )
1124 Proportional_Band_Parameter: URIRef
1125 Proportional_Gain_Parameter: URIRef
1126 Pump: URIRef # Machine for imparting energy to a fluid, causing it to do work, drawing a fluid into itself through an entrance port, and forcing the fluid out through an exhaust port.
1127 Pump_Command: URIRef # Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity)
1128 Pump_On_Off_Status: URIRef
1129 Pump_Room: URIRef # A mechanical room that houses pumps
1130 Pump_VFD: URIRef # Variable-frequency drive for pumps
1131 Quantity: URIRef
1132 RC_Panel: URIRef # See Radiant_Ceiling_Panel
1133 RTU: URIRef # see Rooftop_Unit
1134 RVAV: URIRef # See Variable_Air_Volume_Box_With_Reheat
1135 Radiant_Ceiling_Panel: URIRef # Radiant panel heating and cooling system that are usually made from metal and suspended under the ceiling or insulated from the building structure.
1136 Radiant_Panel: URIRef # A temperature-controlled surface that provides fifty percent (50%) or more of the design heat transfer by thermal radiation.
1137 Radiant_Panel_Temperature_Sensor: URIRef # Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system.
1138 Radiant_Panel_Temperature_Setpoint: URIRef # Sets temperature of radiant panel.
1139 Radiation_Hot_Water_System: URIRef
1140 Radiator: URIRef # Heat exchangers designed to transfer thermal energy from one medium to another
1141 Radioactivity_Concentration_Sensor: (
1142 URIRef # Measures the concentration of radioactivity
1143 )
1144 Radon_Concentration_Sensor: (
1145 URIRef # Measures the concentration of radioactivity due to radon
1146 )
1147 Rain_Duration_Sensor: (
1148 URIRef # Measures the duration of precipitation within some time frame
1149 )
1150 Rain_Sensor: URIRef # Measures the amount of precipitation fallen
1151 Rated_Speed_Setpoint: URIRef # Sets rated speed
1152 Reactive_Power_Sensor: URIRef # Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle
1153 Reception: URIRef # A space, usually in a lobby, where visitors to a building or space can go to after arriving at a building and inform building staff that they have arrived
1154 Region: URIRef # A unit of geographic space, usually contiguous or somehow related to a geopolitical feature
1155 Reheat_Hot_Water_System: URIRef
1156 Reheat_Valve: URIRef # A valve that controls air temperature by modulating the amount of hot water flowing through a reheat coil
1157 Relative_Humidity_Sensor: URIRef # Measures the present state of absolute humidity relative to a maximum humidity given the same temperature
1158 Relief_Damper: URIRef # A damper that is a component of a Relief Air System, ensuring building doesn't become over-pressurised
1159 Relief_Fan: URIRef # A fan that is a component of a Relief Air System, ensuring building doesn't become over-pressurised
1160 Remotely_On_Off_Status: URIRef
1161 Reset_Command: (
1162 URIRef # Commands that reset a flag, property or value to its default
1163 )
1164 Reset_Setpoint: URIRef # Setpoints used in reset strategies
1165 Rest_Room: URIRef # A room that provides toilets and washbowls. Alternate spelling of Restroom
1166 Restroom: URIRef # A room that provides toilets and washbowls.
1167 Retail_Room: URIRef # A space set aside for retail in a larger establishment, e.g. a gift shop in a hospital
1168 Return_Air: URIRef # air removed from a space to be recirculated or exhausted. Air extracted from a space and totally or partially returned to an air conditioner, furnace, or other heating, cooling, or ventilating system.
1169 Return_Air_CO2_Sensor: URIRef # Measures the concentration of CO2 in return air
1170 Return_Air_CO2_Setpoint: URIRef # Sets some property of CO2 in Return Air
1171 Return_Air_CO_Sensor: URIRef # Measures the concentration of CO in return air
1172 Return_Air_Dewpoint_Sensor: URIRef # Senses the dewpoint temperature of return air
1173 Return_Air_Differential_Pressure_Sensor: (
1174 URIRef # Measures the difference in pressure between the return and supply side
1175 )
1176 Return_Air_Differential_Pressure_Setpoint: URIRef # Sets the target air differential pressure between an upstream and downstream point in a return air duct or conduit
1177 Return_Air_Enthalpy_Sensor: URIRef # Measures the total heat content of return air
1178 Return_Air_Filter: URIRef # Filters return air
1179 Return_Air_Flow_Sensor: URIRef # Measures the rate of flow of return air
1180 Return_Air_Grains_Sensor: URIRef # Measures the mass of water vapor in return air
1181 Return_Air_Humidity_Sensor: URIRef # Measures the relative humidity of return air
1182 Return_Air_Humidity_Setpoint: URIRef # Humidity setpoint for return air
1183 Return_Air_Plenum: URIRef # A component of the HVAC the receives air from the room to recirculate or exhaust to or from the building
1184 Return_Air_Temperature_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with the temperature of return air.
1185 Return_Air_Temperature_High_Reset_Setpoint: URIRef
1186 Return_Air_Temperature_Low_Reset_Setpoint: URIRef
1187 Return_Air_Temperature_Sensor: URIRef # Measures the temperature of return air
1188 Return_Air_Temperature_Setpoint: URIRef # The target temperature for return air, often used as an approximation of zone air temperature
1189 Return_Chilled_Water_Temperature_Setpoint: URIRef # Sets the temperature of return (downstream of the chilled water load) chilled water
1190 Return_Condenser_Water: URIRef # In a condenser water loop, this is water being brought away from the condenser side of a heat-rejection device (e.g. chiller). It is the 'warm' side.
1191 Return_Condenser_Water_Flow_Sensor: (
1192 URIRef # Measures the flow of the return condenser water
1193 )
1194 Return_Condenser_Water_Temperature_Sensor: (
1195 URIRef # Measures the temperature of the return condenser water
1196 )
1197 Return_Condenser_Water_Temperature_Setpoint: (
1198 URIRef # The temperature setpoint for the return condenser water
1199 )
1200 Return_Damper: URIRef # A damper that modulates the flow of return air
1201 Return_Fan: URIRef # Fan moving return air -- air that is circulated from the building back into the HVAC system
1202 Return_Heating_Valve: (
1203 URIRef # A valve installed on the return side of a heat exchanger
1204 )
1205 Return_Hot_Water: URIRef
1206 Return_Hot_Water_Temperature_Setpoint: URIRef # Sets the temperature of return (downstream of the hot water load) hot water
1207 Return_Water: (
1208 URIRef # The water is a system after it is used in a heat transfer cycle
1209 )
1210 Return_Water_Flow_Sensor: URIRef
1211 Return_Water_Temperature_Sensor: URIRef # Measures the temperature of return water
1212 Return_Water_Temperature_Setpoint: URIRef # Sets the temperature of return water
1213 Riser: URIRef # A vertical shaft indented for installing building infrastructure e.g., electrical wire, network communication wire, plumbing, etc
1214 Rooftop: URIRef
1215 Rooftop_Unit: URIRef # Packaged air conditioner mounted on a roof, the conditioned air being discharged directly into the rooms below or through a duct system.
1216 Room: URIRef # Base class for all more specific room types.
1217 Room_Air_Temperature_Setpoint: URIRef # Sets temperature of room air
1218 Run_Enable_Command: URIRef
1219 Run_Request_Status: (
1220 URIRef # Indicates if a request has been filed to start a device or equipment
1221 )
1222 Run_Status: URIRef
1223 Run_Time_Sensor: URIRef # Measures the duration for which a device was in an active or "on" state
1224 Safety_Equipment: URIRef
1225 Safety_Shower: URIRef
1226 Safety_System: URIRef
1227 Sash_Position_Sensor: URIRef # Measures the current position of a sash in terms of the percent of fully open
1228 Schedule_Temperature_Setpoint: (
1229 URIRef # The current setpoint as indicated by the schedule
1230 )
1231 Security_Equipment: URIRef
1232 Security_Service_Room: (
1233 URIRef # A class of spaces used by the security staff of a facility
1234 )
1235 Sensor: URIRef # A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary).
1236 Server_Room: URIRef
1237 Service_Room: URIRef # A class of spaces related to the operations of building subsystems, e.g. HVAC, electrical, IT, plumbing, etc
1238 Setpoint: (
1239 URIRef # A Setpoint is an input value at which the desired property is set
1240 )
1241 Shading_System: URIRef # Devices that can control daylighting through various means
1242 Shared_Office: URIRef # An office used by multiple people
1243 Short_Cycle_Alarm: URIRef # An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle
1244 Shower: URIRef # A space containing showers, usually adjacent to an athletic or execise area
1245 Site: URIRef # A geographic region containing 0 or more buildings. Typically used as the encapsulating location for a collection of Brick entities through the hasSite/isSiteOf relationships
1246 Smoke_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with smoke.
1247 Smoke_Detection_Alarm: URIRef
1248 Solar_Azimuth_Angle_Sensor: URIRef # Measures the azimuth angle of the sun
1249 Solar_Radiance_Sensor: URIRef # The amount of light that passes through or is emitted from the sun and falls within a given solid angle in a specified direction
1250 Solar_Thermal_Collector: URIRef # A type of solar panels that converts solar radiation into thermal energy.
1251 Solar_Zenith_Angle_Sensor: URIRef # Measures the zenith angle of the sun
1252 Solid: URIRef # one of the three states or phases of matter characterized by stability of dimensions, relative incompressibility, and molecular motion held to limited oscillation.
1253 Space: URIRef # A part of the physical world or a virtual world whose 3D spatial extent is bounded actually or theoretically, and provides for certain functions within the zone it is contained in.
1254 Space_Heater: URIRef # A heater used to warm the air in an enclosed area, such as a room or office
1255 Speed_Reset_Command: URIRef
1256 Speed_Sensor: URIRef # Measures the magnitude of velocity of some form of movement
1257 Speed_Setpoint: URIRef # Sets speed
1258 Speed_Setpoint_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint.
1259 Speed_Status: (
1260 URIRef # Indicates the operating speed of a device or equipment, e.g. fan
1261 )
1262 Sports_Service_Room: URIRef # A class of spaces used in the support of sports
1263 Stage_Enable_Command: URIRef # A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property
1264 Stage_Riser: URIRef # A low platform in a space or on a stage
1265 Stages_Status: URIRef # Indicates which stage a control loop or equipment is in
1266 Staircase: URIRef # A vertical space containing stairs
1267 Standby_CRAC: URIRef # A CRAC that is activated as part of a lead/lag operation or when an alarm occurs in a primary unit
1268 Standby_Fan: URIRef # Fan that is activated as part of a lead/lag operation or when a primary fan raises an alarm
1269 Standby_Glycool_Unit_On_Off_Status: (
1270 URIRef # Indicates the on/off status of a standby glycool unit
1271 )
1272 Standby_Load_Shed_Command: URIRef
1273 Standby_Unit_On_Off_Status: URIRef # Indicates the on/off status of a standby unit
1274 Start_Stop_Command: URIRef # A Start/Stop Command controls or reports the active/inactive status of a control sequence
1275 Start_Stop_Status: URIRef # Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose)
1276 Static_Pressure_Deadband_Setpoint: (
1277 URIRef # Sets the size of a deadband of static pressure
1278 )
1279 Static_Pressure_Integral_Time_Parameter: URIRef
1280 Static_Pressure_Proportional_Band_Parameter: URIRef
1281 Static_Pressure_Sensor: URIRef # Measures resistance to airflow in a heating and cooling system's components and duct work
1282 Static_Pressure_Setpoint: URIRef # Sets static pressure
1283 Static_Pressure_Setpoint_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint.
1284 Static_Pressure_Step_Parameter: URIRef
1285 Status: URIRef # A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'
1286 Steam: URIRef # water in the vapor phase.
1287 Steam_Baseboard_Radiator: (
1288 URIRef # Steam heating device located at or near the floor
1289 )
1290 Steam_Distribution: URIRef # Utilize a steam distribution source to represent how steam is distributed across multiple destinations
1291 Steam_On_Off_Command: URIRef
1292 Steam_Radiator: URIRef # Radiator that uses steam
1293 Steam_System: URIRef # The equipment, devices and conduits that handle the production and distribution of steam in a building
1294 Steam_Usage_Sensor: URIRef # Measures the amount of steam that is consumed or used, over some period of time
1295 Steam_Valve: URIRef
1296 Step_Parameter: URIRef
1297 Storage_Room: URIRef # A class of spaces used for storage
1298 Storey: URIRef
1299 Studio: URIRef # A room used for the production or media, usually with either a specialized set or a specialized sound booth for recording
1300 Substance: URIRef
1301 Supply_Air: URIRef # (1) air delivered by mechanical or natural ventilation to a space, composed of any combination of outdoor air, recirculated air, or transfer air. (2) air entering a space from an air-conditioning, heating, or ventilating apparatus for the purpose of comfort conditioning. Supply air is generally filtered, fan forced, and either heated, cooled, humidified, or dehumidified as necessary to maintain specified conditions. Only the quantity of outdoor air within the supply airflow may be used as replacement air.
1302 Supply_Air_Differential_Pressure_Sensor: URIRef # Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building
1303 Supply_Air_Differential_Pressure_Setpoint: URIRef # Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit
1304 Supply_Air_Duct_Pressure_Status: (
1305 URIRef # Indicates if air pressure in supply duct is within expected bounds
1306 )
1307 Supply_Air_Flow_Demand_Setpoint: (
1308 URIRef # Sets the rate of supply air flow required for a process
1309 )
1310 Supply_Air_Flow_Sensor: URIRef # Measures the rate of flow of supply air
1311 Supply_Air_Flow_Setpoint: URIRef # Sets supply air flow rate
1312 Supply_Air_Humidity_Sensor: URIRef # Measures the relative humidity of supply air
1313 Supply_Air_Humidity_Setpoint: URIRef # Humidity setpoint for supply air
1314 Supply_Air_Integral_Gain_Parameter: URIRef
1315 Supply_Air_Plenum: URIRef # A component of the HVAC the receives air from the air handling unit to distribute to the building
1316 Supply_Air_Proportional_Gain_Parameter: URIRef
1317 Supply_Air_Static_Pressure_Deadband_Setpoint: (
1318 URIRef # Sets the size of a deadband of static pressure of supply air
1319 )
1320 Supply_Air_Static_Pressure_Integral_Time_Parameter: URIRef
1321 Supply_Air_Static_Pressure_Proportional_Band_Parameter: URIRef
1322 Supply_Air_Static_Pressure_Sensor: (
1323 URIRef # The static pressure of air within supply regions of an HVAC system
1324 )
1325 Supply_Air_Static_Pressure_Setpoint: URIRef # Sets static pressure of supply air
1326 Supply_Air_Temperature_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with the temperature of supply air.
1327 Supply_Air_Temperature_Deadband_Setpoint: (
1328 URIRef # Sets the size of a deadband of temperature of supply air
1329 )
1330 Supply_Air_Temperature_High_Reset_Setpoint: URIRef
1331 Supply_Air_Temperature_Low_Reset_Setpoint: URIRef
1332 Supply_Air_Temperature_Proportional_Band_Parameter: URIRef
1333 Supply_Air_Temperature_Reset_Differential_Setpoint: URIRef
1334 Supply_Air_Temperature_Sensor: URIRef # Measures the temperature of supply air
1335 Supply_Air_Temperature_Setpoint: URIRef # Temperature setpoint for supply air
1336 Supply_Air_Temperature_Step_Parameter: URIRef
1337 Supply_Air_Velocity_Pressure_Sensor: URIRef
1338 Supply_Chilled_Water: URIRef
1339 Supply_Chilled_Water_Temperature_Setpoint: (
1340 URIRef # Temperature setpoint for supply chilled water
1341 )
1342 Supply_Condenser_Water: URIRef # In a condenser water loop, this is water being brought to the condenser side of a heat-rejection device (e.g. chiller). It is the 'cold' side.
1343 Supply_Condenser_Water_Flow_Sensor: (
1344 URIRef # Measures the flow of the supply condenser water
1345 )
1346 Supply_Condenser_Water_Temperature_Sensor: (
1347 URIRef # Measures the temperature of the supply condenser water
1348 )
1349 Supply_Condenser_Water_Temperature_Setpoint: (
1350 URIRef # The temperature setpoint for the supply condenser water
1351 )
1352 Supply_Fan: URIRef # Fan moving supply air -- air that is supplied from the HVAC system into the building
1353 Supply_Hot_Water: URIRef
1354 Supply_Hot_Water_Temperature_Setpoint: (
1355 URIRef # Temperature setpoint for supply hot water
1356 )
1357 Supply_Water: URIRef
1358 Supply_Water_Differential_Pressure_Deadband_Setpoint: (
1359 URIRef # Sets the size of a deadband of differential pressure of supply water
1360 )
1361 Supply_Water_Differential_Pressure_Integral_Time_Parameter: URIRef
1362 Supply_Water_Differential_Pressure_Proportional_Band_Parameter: URIRef
1363 Supply_Water_Flow_Sensor: URIRef # Measures the rate of flow of hot supply water
1364 Supply_Water_Flow_Setpoint: URIRef # Sets the flow rate of hot supply water
1365 Supply_Water_Temperature_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with temperature of the supply water.
1366 Supply_Water_Temperature_Deadband_Setpoint: (
1367 URIRef # Sets the size of a deadband of temperature of supply water
1368 )
1369 Supply_Water_Temperature_Integral_Time_Parameter: URIRef
1370 Supply_Water_Temperature_Proportional_Band_Parameter: URIRef
1371 Supply_Water_Temperature_Setpoint: URIRef # Sets temperature of supply water
1372 Surveillance_Camera: URIRef
1373 Switch: URIRef # A switch used to operate all or part of a lighting installation
1374 Switch_Room: URIRef # A telecommuncations room housing network switches
1375 Switchgear: URIRef # A main disconnect or service disconnect feeds power to a switchgear, which then distributes power to the rest of the building through smaller amperage-rated disconnects.
1376 System: URIRef # A System is a combination of equipment and auxiliary devices (e.g., controls, accessories, interconnecting means, and terminal elements) by which energy is transformed so it performs a specific function such as HVAC, service water heating, or lighting. (ASHRAE Dictionary).
1377 System_Enable_Command: URIRef # Enables operation of a system
1378 System_Shutdown_Status: URIRef # Indicates if a system has been shutdown
1379 System_Status: URIRef # Indicates properties of the activity of a system
1380 TABS_Panel: URIRef # See Thermally_Activated_Building_System_Panel
1381 TETRA_Room: URIRef # A room used for local two-way radio networks, e.g. the portable radios carried by facilities staff
1382 TVOC_Level_Sensor: URIRef # A sensor measuring the level of all VOCs in air
1383 TVOC_Sensor: URIRef
1384 Team_Room: URIRef # An office used by multiple team members for specific work tasks. Distinct from Conference Room
1385 Telecom_Room: (
1386 URIRef # A class of spaces used to support telecommuncations and IT equipment
1387 )
1388 Temperature_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with temperature.
1389 Temperature_Deadband_Setpoint: URIRef # Sets the size of a deadband of temperature
1390 Temperature_Differential_Reset_Setpoint: URIRef
1391 Temperature_High_Reset_Setpoint: URIRef
1392 Temperature_Low_Reset_Setpoint: URIRef
1393 Temperature_Parameter: (
1394 URIRef # Parameters relevant to temperature-related systems and points
1395 )
1396 Temperature_Sensor: URIRef # Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold
1397 Temperature_Setpoint: URIRef # Sets temperature
1398 Temperature_Step_Parameter: URIRef
1399 Temperature_Tolerance_Parameter: URIRef # A parameter determining the difference between upper and lower limits of temperature.
1400 Temporary_Occupancy_Status: URIRef # For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied
1401 Terminal_Unit: URIRef # A device that regulates the volumetric flow rate and/or the temperature of the controlled medium.
1402 Thermal_Power_Meter: URIRef # A standalone thermal power meter
1403 Thermal_Power_Sensor: URIRef
1404 Thermally_Activated_Building_System_Panel: URIRef # Radiant panel heating and cooling system where the energy heat source or sink is embedded in the building structure such as in slabs and walls.
1405 Thermostat: URIRef # An automatic control device used to maintain temperature at a fixed or adjustable setpoint.
1406 Ticketing_Booth: URIRef # A room or space used to sell or distribute tickets to events at a venue
1407 Time_Parameter: URIRef
1408 Time_Setpoint: URIRef
1409 Tolerance_Parameter: URIRef # difference between upper and lower limits of size for a given nominal dimension or value.
1410 Torque_Sensor: URIRef # Measures torque, the tendency of a force to rotate an object about some axis
1411 Touchpanel: URIRef # A switch used to operate all or part of a lighting installation that uses a touch-based mechanism (typically resistive or capacitive) rather than a mechanical actuator
1412 Trace_Heat_Sensor: URIRef # Measures the surface temperature of pipelines carrying temperature-sensitive products; typically used to avoid frosting/freezing
1413 Transformer: URIRef # A Transformer is usually fed by a high-voltage source and then steps down the voltage to a lower-voltage feed for low-voltage application (such as lights). Transformers also can step up voltage, but this generally does not apply to in building distribution.
1414 Transformer_Room: URIRef # An electrical room where electricity enters and is transformed to different voltages and currents by the equipment contained in the room
1415 Tunnel: URIRef # An enclosed space that connects buildings. Often underground
1416 Underfloor_Air_Plenum: URIRef # An open space between a structural concrete slab and the underside of a raised access floor system that connects to an air handling unit to receive conditioned and/or ventilating air before delivery to the room(s)
1417 Underfloor_Air_Plenum_Static_Pressure_Sensor: URIRef # Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum
1418 Underfloor_Air_Plenum_Static_Pressure_Setpoint: (
1419 URIRef # Sets the underfloor air plenum static pressure
1420 )
1421 Underfloor_Air_Temperature_Sensor: (
1422 URIRef # Measures the temperature of underfloor air
1423 )
1424 Unit_Failure_Alarm: (
1425 URIRef # An alarm that indicates the failure of an equipment or device
1426 )
1427 Unoccupied_Air_Temperature_Cooling_Setpoint: (
1428 URIRef # Sets temperature of air when unoccupied for cooling
1429 )
1430 Unoccupied_Air_Temperature_Heating_Setpoint: (
1431 URIRef # Sets temperature of air when unoccupied for heating
1432 )
1433 Unoccupied_Air_Temperature_Setpoint: (
1434 URIRef # Sets temperature of air when unoccupied
1435 )
1436 Unoccupied_Cooling_Discharge_Air_Flow_Setpoint: (
1437 URIRef # Sets discharge air flow for cooling when unoccupied
1438 )
1439 Unoccupied_Discharge_Air_Temperature_Setpoint: URIRef
1440 Unoccupied_Load_Shed_Command: URIRef
1441 Unoccupied_Return_Air_Temperature_Setpoint: URIRef
1442 Unoccupied_Room_Air_Temperature_Setpoint: URIRef
1443 Unoccupied_Supply_Air_Temperature_Setpoint: URIRef
1444 Unoccupied_Zone_Air_Temperature_Setpoint: URIRef
1445 Usage_Sensor: URIRef # Measures the amount of some substance that is consumed or used, over some period of time
1446 VAV: URIRef # See Variable_Air_Volume_Box
1447 VFD: URIRef # Electronic device that varies its output frequency to vary the rotating speed of a motor, given a fixed input frequency. Used with fans or pumps to vary the flow in the system as a function of a maintained pressure.
1448 VFD_Enable_Command: URIRef # Enables operation of a variable frequency drive
1449 Valve: URIRef # A device that regulates, directs or controls the flow of a fluid by opening, closing or partially obstructing various passageways
1450 Valve_Command: URIRef # Controls or reports the openness of a valve (typically as a proportion of its full range of motion)
1451 Valve_Position_Sensor: URIRef # Measures the current position of a valve in terms of the percent of fully open
1452 Variable_Air_Volume_Box: URIRef # A device that regulates the volume and temperature of air delivered to a zone by opening or closing a damper
1453 Variable_Air_Volume_Box_With_Reheat: URIRef # A VAV box with a reheat coil mounted on the discharge end of the unit that can heat the air delivered to a zone
1454 Variable_Frequency_Drive: URIRef # Electronic device that varies its output frequency to vary the rotating speed of a motor, given a fixed input frequency. Used with fans or pumps to vary the flow in the system as a function of a maintained pressure.
1455 Velocity_Pressure_Sensor: (
1456 URIRef # Measures the difference between total pressure and static pressure
1457 )
1458 Velocity_Pressure_Setpoint: URIRef # Sets static veloicty pressure
1459 Vent_Operating_Mode_Status: URIRef # Indicates the current operating mode of a vent
1460 Ventilation_Air_Flow_Ratio_Limit: URIRef # A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint.
1461 Ventilation_Air_System: URIRef # The equipment, devices, and conduits that handle the introduction and distribution of ventilation air in the building
1462 Vertical_Space: (
1463 URIRef # A class of spaces used to connect multiple floors or levels..
1464 )
1465 Video_Intercom: URIRef
1466 Video_Surveillance_Equipment: URIRef
1467 Visitor_Lobby: URIRef # A lobby for visitors to the building. Sometimes used to distinguish from an employee entrance looby
1468 Voltage_Imbalance_Sensor: URIRef # A sensor which measures the voltage difference (imbalance) between phases of an electrical system
1469 Voltage_Sensor: URIRef # Measures the voltage of an electrical device or object
1470 Wardrobe: URIRef # Storage for clothing, costumes, or uniforms
1471 Warm_Cool_Adjust_Sensor: URIRef # User provided adjustment of zone temperature, typically in the range of +/- 5 degrees
1472 Warmest_Zone_Air_Temperature_Sensor: URIRef # The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor'
1473 Waste_Storage: URIRef # A room used for storing waste such as trash or recycling
1474 Water: URIRef # transparent, odorless, tasteless liquid; a compound of hydrogen and oxygen (H2O), containing 11.188% hydrogen and 88.812% oxygen by mass; freezing at 32°F (0°C); boiling near 212°F (100°C).
1475 Water_Alarm: URIRef # Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak
1476 Water_Differential_Pressure_Setpoint: URIRef # Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit
1477 Water_Differential_Temperature_Sensor: URIRef # Measures the difference in water temperature between an upstream and downstream point in a pipe or conduit
1478 Water_Differential_Temperature_Setpoint: URIRef # Sets the target differential temperature between the start and end of a heat transfer cycle in a water circuit
1479 Water_Distribution: URIRef # Utilize a water distribution source to represent how water is distributed across multiple destinations (pipes)
1480 Water_Flow_Sensor: URIRef # Measures the rate of flow of water
1481 Water_Flow_Setpoint: URIRef # Sets the target flow rate of water
1482 Water_Heater: URIRef # An apparatus for heating and usually storing hot water
1483 Water_Level_Alarm: (
1484 URIRef # An alarm that indicates a high or low water level e.g. in a basin
1485 )
1486 Water_Level_Sensor: URIRef # Measures the height/level of water in some container
1487 Water_Loop: URIRef # A collection of equipment that transport and regulate water among each other
1488 Water_Loss_Alarm: (
1489 URIRef # An alarm that indicates a loss of water e.g. during transport
1490 )
1491 Water_Meter: URIRef # A meter that measures the usage or consumption of water
1492 Water_Pump: URIRef # A pump that performs work on water
1493 Water_System: URIRef # The equipment, devices and conduits that handle the production and distribution of water in a building
1494 Water_Tank: URIRef # A space used to hold water
1495 Water_Temperature_Alarm: URIRef # An alarm that indicates the off-normal conditions associated with temperature of water.
1496 Water_Temperature_Sensor: URIRef # Measures the temperature of water
1497 Water_Temperature_Setpoint: URIRef # Sets temperature of water
1498 Water_Usage_Sensor: URIRef # Measures the amount of water that is consumed, over some period of time
1499 Water_Valve: URIRef # A valve that modulates the flow of water
1500 Weather_Station: URIRef # A dedicated weather measurement station
1501 Wind_Direction_Sensor: (
1502 URIRef # Measures the direction of wind in degrees relative to North
1503 )
1504 Wind_Speed_Sensor: (
1505 URIRef # Measured speed of wind, caused by air moving from high to low pressure
1506 )
1507 Wing: URIRef # A wing is part of a building – or any feature of a building – that is subordinate to the main, central structure.
1508 Workshop: URIRef # A space used to house equipment that can be used to repair or fabricate things
1509 Zone: URIRef # (1) a separately controlled heated or cooled space. (2) one occupied space or several occupied spaces with similar occupancy category, occupant density, zone air distribution effectiveness, and zone primary airflow per unit area. (3) space or group of spaces within a building for which the heating, cooling, or lighting requirements are sufficiently similar that desired conditions can be maintained throughout by a single controlling device.
1510 Zone_Air: URIRef # air inside a defined zone (e.g., corridors).
1511 Zone_Air_Cooling_Temperature_Setpoint: (
1512 URIRef # The upper (cooling) setpoint for zone air temperature
1513 )
1514 Zone_Air_Dewpoint_Sensor: URIRef # Measures dewpoint of zone air
1515 Zone_Air_Heating_Temperature_Setpoint: (
1516 URIRef # The lower (heating) setpoint for zone air temperature
1517 )
1518 Zone_Air_Humidity_Sensor: URIRef # Measures the relative humidity of zone air
1519 Zone_Air_Humidity_Setpoint: URIRef # Humidity setpoint for zone air
1520 Zone_Air_Temperature_Sensor: URIRef # Measures the temperature of air in a zone
1521 Zone_Air_Temperature_Setpoint: URIRef # Sets temperature of zone air
1522 Zone_Standby_Load_Shed_Command: URIRef
1523 Zone_Unoccupied_Load_Shed_Command: URIRef
1524
1525 # http://www.w3.org/2002/07/owl#Property
1526 feeds: URIRef # The subject is upstream of the object in the context of some sequential process; some media is passed between them
1527 feedsAir: URIRef # Passes air
1528 hasAddress: URIRef # To specify the address of a building.
1529 hasAssociatedTag: URIRef # The class is associated with the given tag
1530 hasInputSubstance: URIRef # The subject receives the given substance as an input to its internal process
1531 hasLocation: (
1532 URIRef # Subject is physically located in the location given by the object
1533 )
1534 hasOutputSubstance: URIRef # The subject produces or exports the given substance from its internal process
1535 hasPart: URIRef # The subject is composed in part of the entity given by the object
1536 hasPoint: URIRef # The subject has a source of telemetry identified by the object. In some systems the source of telemetry may be represented as a digital/analog input/output point
1537 hasQUDTReference: URIRef # Points to the relevant QUDT definition
1538 hasTag: URIRef # The subject has the given tag
1539 hasTimeseriesId: URIRef # The unique identifier (primary key) for this TimeseriesReference in some database
1540 hasUnit: URIRef # The QUDT unit associated with this Brick entity (usually a Brick Point instance or Entity Property)
1541 isAssociatedWith: URIRef # The tag is associated with the given class
1542 isFedBy: URIRef
1543 isLocationOf: URIRef # Subject is the physical location encapsulating the object
1544 isMeasuredBy: URIRef
1545 isPartOf: URIRef
1546 isPointOf: URIRef # The subject is a source of telemetry related to the object. In some systems the source of telemetry may be represented as a digital/analog input/output point
1547 isRegulatedBy: URIRef
1548 isTagOf: URIRef
1549 latitude: URIRef
1550 longitude: URIRef
1551 measures: URIRef # The subject measures a quantity or substance given by the object
1552 regulates: URIRef # The subject contributes to or performs the regulation of the substance given by the object
1553 storedAt: (
1554 URIRef # A reference to where the data for this TimeseriesReference is stored
1555 )
1556 timeseries: URIRef # Relates a Brick point to the TimeseriesReference that indicates where and how the data for this point is stored
1557 value: URIRef # The basic value of an entity property
1558
1559 # https://brickschema.org/schema/Brick#EntityProperty
1560 aggregate: URIRef # Description of how the dta for this point is aggregated
1561 area: URIRef # Entity has 2-dimensional area
1562 azimuth: URIRef # (Horizontal) angle between a projected vector and a reference vector (typically a compass bearing). The projected vector usually indicates the direction of a face or plane.
1563 buildingPrimaryFunction: URIRef # Enumerated string applied to a site record to indicate the building's primary function. The list of primary functions is derived from the US Energy Star program (adopted from Project Haystack)
1564 buildingThermalTransmittance: URIRef # The area-weighted average heat transfer coefficient (commonly referred to as a U-value) for a building envelope
1565 conversionEfficiency: URIRef # The percent efficiency of the conversion process (usually to power or energy) carried out by the entity
1566 coolingCapacity: URIRef # Measurement of a chiller ability to remove heat (adopted from Project Haystack)
1567 coordinates: URIRef # The location of an entity in latitude/longitude
1568 currentFlowType: URIRef # The current flow type of the entity
1569 electricalPhaseCount: URIRef # Entity has these phases
1570 electricalPhases: URIRef # Entity has these electrical AC phases
1571 grossArea: URIRef # Entity has gross 2-dimensional area
1572 measuredModuleConversionEfficiency: URIRef # The measured percentage of sunlight that is converted into usable power
1573 measuredPowerOutput: URIRef # The nominal measured power output of the entity
1574 netArea: URIRef # Entity has net 2-dimensional area
1575 operationalStage: URIRef # The associated operational stage
1576 operationalStageCount: (
1577 URIRef # The number of operational stages supported by this eqiupment
1578 )
1579 panelArea: URIRef # Surface area of a panel, such as a PV panel
1580 powerComplexity: URIRef # Entity has this power complexity
1581 powerFlow: URIRef # Entity has this power flow relative to the building'
1582 ratedModuleConversionEfficiency: URIRef # The *rated* percentage of sunlight that is converted into usable power, as measured using Standard Test Conditions (STC): 1000 W/sqm irradiance, 25 degC panel temperature, no wind
1583 ratedPowerOutput: URIRef # The nominal rated power output of the entity
1584 temperatureCoefficientofPmax: URIRef # The % change in power output for every degree celsius that the entity is hotter than 25 degrees celsius
1585 thermalTransmittance: URIRef # The area-weighted average heat transfer coefficient (commonly referred to as a U-value)
1586 tilt: URIRef # The direction an entity is facing in degrees above the horizon
1587 volume: URIRef # Entity has 3-dimensional volume
1588 yearBuilt: URIRef # Four digit year that a building was first built. (adopted from Project Haystack)
1589
1590 _extras = ["PM2.5_Sensor", "PM2.5_Level_Sensor"]
1591
1592 _NS = Namespace("https://brickschema.org/schema/Brick#")