spec.json
1{
2 "class": "ReichsteinCheck",
3 "description": "EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB.",
4 "params": {
5 "soilTemperatureField": "soil",
6 "frictionWindSpeedField": "wind",
7 "FC": "Fc",
8 "flagValue": -9999,
9 "percentFlux": 0.99
10 },
11 "inputs": {
12 "source": {
13 "representations": [
14 "records"
15 ],
16 "formats": []
17 }
18 },
19 "outputs": {
20 "result": {
21 "representations": [
22 "records"
23 ],
24 "formats": [
25 "arrow"
26 ]
27 }
28 },
29 "mode": "bounded_materialization",
30 "test": "reichstein_check",
31 "parameters": {
32 "type": "object",
33 "properties": {
34 "soilTemperatureField": {
35 "type": "string",
36 "description": "soilTemperatureField parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB."
37 },
38 "frictionWindSpeedField": {
39 "type": "string",
40 "description": "frictionWindSpeedField parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB."
41 },
42 "FC": {
43 "type": "string",
44 "description": "FC parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB."
45 },
46 "flagValue": {
47 "type": "integer",
48 "description": "flagValue parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB."
49 },
50 "percentFlux": {
51 "type": "number",
52 "description": "percentFlux parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB.",
53 "minimum": 0,
54 "maximum": 1
55 }
56 },
57 "required": [
58 "soilTemperatureField",
59 "frictionWindSpeedField",
60 "FC",
61 "flagValue",
62 "percentFlux"
63 ],
64 "additionalProperties": false
65 },
66 "icon": {
67 "path": "M3 5h18v14H3zM3 10h18M3 14h18M9 5v14"
68 }
69}