Source code

Download source archive ↓

spec.json

1{
2  "class": "ReichsteinCheck",
3  "description": "EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB.",
4  "params": {
5    "soilTemperatureField": "soil",
6    "frictionWindSpeedField": "wind",
7    "FC": "Fc",
8    "flagValue": -9999,
9    "percentFlux": 0.99
10  },
11  "inputs": {
12    "source": {
13      "representations": [
14        "records"
15      ],
16      "formats": []
17    }
18  },
19  "outputs": {
20    "result": {
21      "representations": [
22        "records"
23      ],
24      "formats": [
25        "arrow"
26      ]
27    }
28  },
29  "mode": "bounded_materialization",
30  "test": "reichstein_check",
31  "parameters": {
32    "type": "object",
33    "properties": {
34      "soilTemperatureField": {
35        "type": "string",
36        "description": "soilTemperatureField parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB."
37      },
38      "frictionWindSpeedField": {
39        "type": "string",
40        "description": "frictionWindSpeedField parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB."
41      },
42      "FC": {
43        "type": "string",
44        "description": "FC parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB."
45      },
46      "flagValue": {
47        "type": "integer",
48        "description": "flagValue parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB."
49      },
50      "percentFlux": {
51        "type": "number",
52        "description": "percentFlux parameter. EcoFlow Reichstein u-star screening implemented without Spark: six equal-count temperature groups, twenty wind bins, Pearson<0.4, median valid threshold; flag nighttime low-wind FC. Params soilTemperatureField,frictionWindSpeedField,FC strings,flagValue int32,percentFlux numeric(0,1]. Excludes null/nonfinite/flagged samples from estimation; requires120 valid observations. Fixes upper-bin bound and deterministic threshold order. Bounded128MiB.",
53        "minimum": 0,
54        "maximum": 1
55      }
56    },
57    "required": [
58      "soilTemperatureField",
59      "frictionWindSpeedField",
60      "FC",
61      "flagValue",
62      "percentFlux"
63    ],
64    "additionalProperties": false
65  },
66  "icon": {
67    "path": "M3 5h18v14H3zM3 10h18M3 14h18M9 5v14"
68  }
69}